350-E-P1-G1-H-E-M-C-N-3E-D-N

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
General Electric 350-E-P1-G1-H-E-M-C-N-3E-D-N Multilin Feeder Protective Device Multilin 350 Protection System

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Contact: 1-919-372-8413 (Intl.), 1-800-991-7026 (US), sales@axcontrol.com

Warranty: Learn More

Sell Surplus: Have a 350-E-P1-G1-H-E-M-C-N-3E-D-N to sell? Sell Now

Exchange Credit: Learn more about our exchange credit program

350-E-P1-G1-H-E-M-C-N-3E-D-N

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
General Electric 350-E-P1-G1-H-E-M-C-N-3E-D-N Multilin Feeder Protective Device Multilin 350 Protection System

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Contact: 1-919-372-8413 (Intl.), 1-800-991-7026 (US), sales@axcontrol.com

Warranty: Learn More

Sell Surplus: Have a 350-E-P1-G1-H-E-M-C-N-3E-D-N to sell? Sell Now

Exchange Credit: Learn more about our exchange credit program

Product Description

350-E-P1-G1-H-E-M-C-N-3E-D-N is a microprocessor-based relay that is manufactured by GE Multilin for the 350 Feeder Protection System series. This 3-phase relay has 1 amp current inputs and a 1 amp ground current input. The language on this system is english. The power supply is 24 to 28 VDC. This relay has a standard faceplate with 10 inputs and 7 outputs. The current protection has an advanced configuration. There is also a standard communication port and an Ethernet port.

On the phase and ground current inputs, the CT primary is 1 to 6000 A. The range is 0.02 to 20 CT. The input type is 1 A or 5 A. The nominal frequency is 50/60 Hz. The burden is less than 0.1 VA at the rated load. The accuracy is ± 1% of the reading at 1 x CT, ± 3% of the reading from 0.3 to 20 x CT, ± 20% of the reading from 0.02 to 0.19 x CT. The CT withstand is 1 second at 100 x the rated current, 2 seconds at 40 x the rated current, and continuous at 3 x the rated current. On the sensitive ground current input, the CT primary is 1 to 600 A. The range is 0.002 to 3 x CT. On the phase/AUX voltage inputs, the source VT is 0.12 to 65 kV / 50 to 220 V. The VT secondary range is 50 to 240 V. The VT ratio is 1 to 5000 in steps of 1. The accuracy is ± 1.0% throughout the range. The voltage withstand is 260 VAC continuous. The high range of power supply nominal is 120 to 240 VAC or 125 to 250 VDC. The ride-through time is 35 ms. The low range of power supply nominal is 24 to 48 VDC. The voltage withstand is 2 x the highest nominal voltage for 10 ms. The power consumption is 15 watts nominal and 20 watts maximum. The power consumption is also 20 VA nominal and 28 VA maximum.

For additional information about this protection system, please consult GE documentation like GE manuals, user guides, and GE datasheets for this particular unit. 

 

Frequently Asked Questions about 350-E-P1-G1-H-E-M-C-N-3E-D-N

What is the drawout construction option of the GE Multilin 350 feeder protection series 350-E-P1-G1-H-E-M-C-N-3E-D-N device?
The 350-E-P1-G1-H-E-M-C-N-3E-D-N feeder protection relay includes the drawout construction option (D). This option allows the user to completely eliminate the need to rewire after testing. With this option, the user does not need to disconnect communication cables (Ethernet fiber, copper, RJ45) or open switch the gear door before removing the device from the case. The 350-E-P1-G1-H-E-M-C-N-3E-D-N is also very small and compact. May relays can be mounted adjacent to one another in close proximity on a medium voltage panel. If the depth of the compartment is an issue then the 350 has the ability to use reducing collars.
How does the Multilin General Electric 350 feeder protection device 350-E-P1-G1-H-E-M-C-N-3E-D-N allow for preventative maintenance?
The G1-H-E-M-C-N-3E-D-N allows the operator to be able to track and monitor the relay's exposure to harsh or extreme operating conditions by tracking high ambient temperatures and by giving an alarm in this situation. The user can schedule routine maintenance or upgrade activities. This feature simply allows the user to become more aware of the deterioration of electronics over time due to harsh conditions. This 350-E-P1-G1-H-E-M-C-N-3E-D-N is optimal to protect, control, and manage a variety of feeders and their associated applications.
 

Repair Services For 350-E-P1-G1-H-E-M-C-N-3E-D-N

Type Lead Time Price Action
Repair Service 1-2 weeks Ask Get Quote

Our highly skilled technicians can repair your 350-E-P1-G1-H-E-M-C-N-3E-D-N. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More