About the GEM41100
The GEM41100 6-Digit Presettable Counter/Indicator made for Red Lion's GEMINI 1000/2000 Series has two possible reset actions that it can take. These would have to include its:
- Reset-to-Zero Action
- Reset-to-Preset Action
Reset-to-Zero Action activates an output when the count equals the preset value. When reset, this counter turns to zero. With Reset-to-Preset, the output activates when the count equals zero, and the counter returns to preset value when it is reset.
GEM41100 6-Digit Presettable Counter/Indicator Reset Modes
In addition to two possible reset actions, the GEM41100 6-Digit Presettable Counter/Indicator retains a number of additional reset modes, including its:
- Manual Reset Mode
- Automatic Reset at Preset Mode
- Automatic Reset after Output Time Delay Mode
A manual reset of the GEM41100 6-Digit Presettable Counter/Indicator can be both triggered remotely and by the pressing of a pushbutton on the unit's front interface.