Frequently Asked Questions about 1SU41005

What does the NEMA 1 enclosure on 1SU41005 mean?
The NEMA 1 enclosure on a Reliance 1SU41005 indicates the 1SU41005 is vented and 1SU41005 is for general-purpose indoor applications.
What are the dimensions on a Reliance 1SU41005?
At its' tallest height, 1SU41005 is 11.8 inches tall. At 1SU41005's largest width, 1SU41005 is 8.75 inches wide. When turned to the side, 1SU41005 is 6.3 inches wide.
Can AX Control repair my 1SU41005?
Yes, we'd love to repair your 1SU41005. Speak to a sales representative for an estimated repair time and a repair quote on the 1SU41005. We do in-house repairs on all SP500 drives and would be happy to repair your 1SU41005.

Product Description

1SU41005 is an SP500 drive that is manufactured by Reliance Electric. This drive has a rated horsepower of 5.0 HP and is contained in a NEMA 1 or chassis style enclosure. The rated voltage is 380-460 VAC. The enclosure size for this drive is size B. The dimensions of Enclosure B are 301.7 mm (11.88 in) (H) x 160.1 mm (6.3 in) (D) x 222.3 mm (8.75 in) (W). The weight of enclosure B is 5.4 kg (12 lb).

A number of fault codes help the user identify faults on the drive. OL is the code for the motor overload fault. This fault is caused by either excess motor current, excess load on the motor, or a loss of a phase connection. In order to correct this fault, check the motor nameplate amps, check that the motor is sized correctly, reduce load on the motor, and/or check the output lines to the motor. OPL is the code for the motor output phase loss fault. This fault is caused by a phase lost between the drive and the motor. In order to correct this fault, check the connections and cable of all three phases and motor windings. Replace any damaged cable. OSP is the code for the overspeed (vector only) fault. This fault is caused by an RPM above 130% Maximum Speed, and the speed regulator response is not optimized. In order to correct this fault, check the encoder PPR, the motor poles, the base frequency, the motor nameplate rpm speed, the reg. proportional, and the integral gain.

1SU41005 Technical Specifications

Enclosure NEMA 1 or Chassis
HP 5 HP
Hz 50/60Hz
Input Voltage 380-460 VAC
Labeling UL Listed, IEC Certified
Manufacturer Reliance Electric
Part Number ISU41005
Series SP500

1SU41005 Documents

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty.
All PLCs and HMIs: 3 years
All AC/DC and Servo Drives: 2 years
All Motors: 1 year