Reliance SP500 3 Phase Drive NEMA1.

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a 1SU21001 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 1SU21001
  • SKU: 1SU21001RE
  • Manufacturer: Reliance Electric
  • Series: SP500 AC Drives

1SU21001 Technical Specifications

Manufacturer Reliance Electric
Series SP500
Part Number 1SU21001
HP 1 HP
Input Voltage 200-230 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
Labeling UL Listed, IEC Certified

Product Description

1SU21001 is a single phase SP500 drive manufactured by Reliance Electric. The drive has a size A NEMA 1 enclosure. The output is 1.7 amps. The horsepower is 1 HP. The AC input is 200-230 input volts. The input amperes are 5.0 and the input KVA is 1.3. The power loss is 70 watts. The fuse rating is either 10A or 12A. The recommended fuse type is a UL Class J, 600 volts, with a time delay. The associated AC mains filter is 2DF2282.

F-14 is the Electronic Thermal Overload parameter on the SP500 drive. The settings range is 20%-100% of the rated current, and the step size is 1%. If the motor amperage rating is less than the controller amperage rating, the electronic thermal overload should be adjusted. Use the following formula to calculate the electronic thermal overload: motor full load current divided by the controller output rated current, multiplied by 100. F-15 is the Electronic Thermal Overload Disable parameter. When this setting is Off, there is no electronic thermal overload protection. When this setting is on, the thermal overload protection is active. The default setting for this parameter is OFF. F-16 is the Coast Stop Enable parameter. When this parameter is ON, coast-to-rest is enabled. When this parameter is OFF, ramp-to-rest is enabled. F-17 is the Reverse Disable parameter. When this parameter is ON, this drive will not be able to run in reverse. When this parameter is OFF, this drive will be able to run in reverse. F-18 is the Version Information for the SP500 drive. This function cannot be changed.

Frequently Asked Questions about 1SU21001

What does the built-in keypad on the 1SU21001 drive display?
The built-in keypad on the 1SU21001 drive allows you to control your SP500 drive. There is a Start/Stop/Rest control, a Forward/Reverse control, and a Setpoint adjustment control. The built-in keypad on the 1SU21001 drive also displays Motor RPM, % Load, and Output Voltage and has many different drive diagnostic features that you can find in the SP500 installation and operation manual.
If the input voltage on a 1SU21001 drive is 200-230 VAC, what are the input amps and input KVA?
The input amps on a 1SU21001 drive are at 5.0 and the input KVA are at 1.3. While you mention the input voltage, make note that not all SP500 drives that have an input voltage of 200-230 VAC match 5.0 input amps and 1.3 KVA. Any single-phase SP500 drive above 2 HP will have higher input amps and input KVA and any three-phase SP500 drive will have higher input amps and input KVA. 
Can AX Control repair my 1SU21001 drive without deleting my adjusted setting changes?
We recommend that you back up, save, and document any dip switch settings before sending your 1SU21001 SP500 drive in for repair so that we are able to test the full functionality of the drive under default factory settings. If you have put a lot of work into adjusting the settings on your drive, our team members will be happy to help you reset the drive to your preferred settings after the drive has been fully repaired. 
Can the 1SU21001 drive operate under any temperature range?
The 1SU21001 drive can pretty much operate under any typical indoor, outdoor, or room temperature unless you are trying to operate the drive in an area that is typically below freezing. Because the 1SU21001 drive has a NEMA 1 enclosure, it is best that it is used indoors due to the lack of protection on the vented drive cover. This makes it easier for the drive to be at an ambient operating temperature of 32-104 degrees Farenheit. While in storage, the 1SU21001 drive can stay in a location as cold as -40 degrees Farenheit or as hot as 149 degrees Farenheit. The humidty of the setting should be somewhere between 5 and 95 percent non-condensing. 

Repair Services For 1SU21001

Type Lead Time Price Action
Repair Service 1-2 weeks $1182

Our highly skilled technicians can repair your 1SU21001. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

1SU21001 Manuals, White Papers, Data Sheets, and Troubleshooting