6V41-3P4TA

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.75 (4)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.75 (4)
  • Click a star to rate this product
2HP AC Drive

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 6V41-3P4TA to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 6V41-3P4TA
  • SKU: 6V413P4TARE
  • Manufacturer: Reliance Electric
  • Series: GV6000 Drives

6V41-3P4TA Technical Specifications

Manufacturer Reliance Electric
Series GV6000
Part Number 6V41-3P4TA
HP 2 HP
Input Voltage 460 VAC
Enclosure NEMA 1 Air Cooled
Digital Input Voltage 24 VDC
Braking Transistor Included
Labeling UL Listed, IEC Certified

Product Description

6V41-3P4TA is a GV6000 AC Drive that is manufactured by Reliance Electric. The nominal duty horsepower is 2, the continuous amps are 3.4, and the frame is 0. The dimensions of frame 0 are 110 mm x 336 mm x 200 mm x 80 mm x 320 mm. This drive has a 460 VAC input and is enclosed in a NEMA 1 enclosure. A braking transistor comes standard on this unit. The I/O is 24 VDC.

There are a number of fault codes on the drive for troubleshooting purposes. Fault number 49 is a drive power up marker, which is not a fault. This marker indicates that the drive power has been cycled. Fault number 51 is a flt QueueCleared marker that means that the fault queue has been cleared. Fault number 52 is a faults cleared marker that means that the fault queue has been cleared. Fault number 55 is a control BD overload fault, which means that excessive heat has been detected on the temperature sensor on the Main Control Board. To fix this fault, check the main control board fan, the surrounding air temperature, and the mounting/cooling. Fault number 63 is a shear pin fault. Check the current limit value setting; it has been exceeded. Fault number 64 is a drive overload fault, which means that the drive was running at 110% of the rating for one minute, or at 150% of the rating for 3 seconds. Reduce the load or extend the acceleration time.

Frequently Asked Questions about 6V41-3P4TA

If the continuous output amps of a 6V41-3P4TA Reliance Electric GV6000 are 3.4, what are the output amps at one minute?
A 6V41-3P4TA has 3.4 continous output amps at 480 VAC input and a 6V41-3P4TA has 3.5 continuous output amps at 400 VAC input. At 480 VAC input, 6V41-3P4TA has 4.5 output amps at one minute and at 400 VAC input, 6V41-3P4TA also has 4.5 output amps at one minute.
How big is a 6V41-3P4TA?
According to the GV6000 AC Drive User Manual, the frame size of a 6V41-3P4TA is zero. Therefore, a 6V41-3P4TA is 7.87 inches in depth. A 6V41-3P4TA has a height of 13.23 inches, and a 6V41-3P4TA has a width of 4.33 inches. 6V41-3P4TA drives weigh 11.5lbs.
How can I troubleshoot and repair my 6V41-3P4TA?
For basic troubleshooting needs for your 6V41-3P4TA, you can look at the GV6000 AC Drive Manual in the manual's troubleshooting section. The manual provides troubleshooting tables and the manual provides alarm descriptions and fault descriptions. If your 6V41-3P4TA needs to be repaired, AX Control is happy to help repair your 6V41-3P4TA GV6000 drive. Call our sales representative for a repair quote an estimated repair time on your 6V41-3P4TA.
Which parameters on a 6V41-3P4TA are determined by autotune?
On a 6V41-3P4TA, there are four parameters determined by autotune. Parameter 63, the Flux Current Ref parameter, is the flux test parameter that rotates the motor on a 6V41-3P4TA. Parameter 62, the IR Voltage Drop parameter, is set by the IR voltage drop test on a 6V41-3P4TA. Parameter 64, the Ixo Voltage Drop parameter, is the parameter that is set by the leakage inductance test. Parameter 450, the Total Inertia parameter, on a 6V41-3P4TA is set by the intertia test which accelerates the motor on a 6V41-3P4TA from zero to about 2/3 of base motor speed.

Repair Services For 6V41-3P4TA

Type Lead Time Price Action
Repair Service 1-2 weeks $2242

Our highly skilled technicians can repair your 6V41-3P4TA. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More