The Reliance Electric GV3000 series' GV3000E-AC004-AA-DBU-RFI-model is a 3-phase, 50/60Hz bookshelf drive equipped with an input voltage of 380-460 VAC, an input kVA of 4.0 KVA, and 5 A input amps, with an IP20-type enclosure.

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a GV3000E-AC004-AA-DBU-RFI to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: GV3000E-AC004-AA-DBU-RFI
  • SKU: GV3000EAC004AADBURFIRE
  • Manufacturer: Reliance Electric
  • Series: GV3000 Drives

GV3000E-AC004-AA-DBU-RFI Technical Specifications

Part Number GV3000E-AC004-AA-DBU-RFI
US Model Number 38ET4060
European Stock Number 896.02.31
Series GV3000
Manufacturer Reliance Electric
Instruction Manual D2-3426 & D2=3427
Keypad/Display Built-In Keypad
Enclosure IP20
Input Voltage 380-460 VAC
Phase 3 Phase
Hz 50/60Hz
Input KVA 4.0 KVA
Input Amps 5 A
Output Amps in Vector Mode at Frequency of 4 kHz 3.1 A

Product Description

Model number GV3000E-AC004-AA-DBU-RFI is one of the GV3000 drives produced by Reliance Electric. There are two types of GV3000 drives AC drives and bookshelf drives. The GV3000E-AC004-AA-DBU-RFI drive is one of the bookshelf drives. Two part numbers are associated with this drive; one is the US model number 38ET4060, and the other is the European stock number 896.02.31. The US model number indicates whether or not the unit has a CE filter through the third and fourth characters, which for this model is ET, which shows the drive has a CE filter. 

In the GV300-UM060K-EN-P GV3000/SE AC General Purpose and Vector Drive, Version 6.0 Instruction Manual Table 2-8a gives a full breakdown of the GV3000E-AC004-AA-DBU-RFI model number. The first section of the part number is used for identifying the technical data. The technical data for the GV3000 drives are the motor power and the inverter current, which depend on the chosen regulator. The motor power when the drive is in vector mode is 1.1 A at 400 VAC, with the inverter current being 3.1 A at 2 kHz. The last three sections of the part number AA-DBU-RFI indicate the type of drive. This model is a drive with a braking unit, RFI filter, and DC-bus terminals. 

Depending on the amperage that the drive operates on, there are different components on the drive and component locations. The GV3000E-AC004-AA-DBU-RFI drive has a current rating of 3.8 A, meaning that the elements on this drive are a fan, keypad/display, output relay terminal strip, power printed circuit board (PCB), and regulator PCB.

Frequently Asked Questions about GV3000E-AC004-AA-DBU-RFI

Which parameter on GV3000E-AC004-AA-DBU-RFI sets the maximum speed?
Parameter P.004 is the maximum speed parameter on GV3000E-AC004-AA-DBU-RFI. Press the up arrow key on GV3000E-AC004-AA-DBU-RFI to display parameter P.004 and set the parameter to meet the preferred maximum speed for your GV3000E-AC004-AA-DBU-RFI.
What are the bus voltage fault code errors on GV3000E-AC004-AA-DBU-RFI?
There is a high DC bus voltage fault code for GV3000E-AC004-AA-DBU-RFI and a low DC bus voltage fault code for GV3000E-AC004-AA-DBU-RFI. The high DC bus voltage fault error is "HU" and the low fault error is "LU" on GV3000E-AC004-AA-DBU-RFI.
What is the difference between the two manuals for GV3000E-AC004-AA-DBU-RFI?
Both manuals listed, Manual D2-3426 and Manual D2-3427, are important manuals in understanding GV3000E-AC004-AA-DBU-RFI, but the manuals are very different from eachother. Manual D2-3426 is the software start-up manual for GV3000E-AC004-AA-DBU-RFI while Manual D2-3427 is the hardware manual for GV3000E-AC004-AA-DBU-RFI. Both manuals will help you with GV3000E-AC004-AA-DBU-RFI but each manual will help in different ways.
Which fault codes can be auto-reset on GV3000E-AC004-AA-DBU-RFI?
There are 13 fault codes that can be auto-reset on GV3000E-AC004-AA-DBU-RFI. The fault codes are: Aln, bYC, EC, HIL, HU, LU, nCL, OC, OCA, OCb, OH, OL, and UbS. All other fault code errors on GV3000E-AC004-AA-DBU-RFI are non-auto-resettable.

Reviews For GV3000E-AC004-AA-DBU-RFI

Internal Review
(5.0)

The GV3000E-AC004-AA-DBU-RFI model is equipped with an RFI filter; this filter has HF emissions limits of class A, group 1, also known as EN 55011, in the industrial supply network. The RFI filter and drive can be used in industrial estate high-power converters with sensitive consumers connected to the same supply transformer making this model more enhanced than other customizable GV3000E drives. - AX Control Lead Technician

Repair Services For GV3000E-AC004-AA-DBU-RFI

Type Lead Time Price Action
Repair Service 1-2 weeks $1045

Our highly skilled technicians can repair your GV3000E-AC004-AA-DBU-RFI. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

GV3000E-AC004-AA-DBU-RFI Manuals, White Papers, Data Sheets, and Troubleshooting