In Stock
In Stock! Reliance Electric GV-3000 GV3000/SE Sensorless AC 1HP Drive. Call Now! | Image
2 year warranty

In Stock! Reliance Electric GV-3000 GV3000/SE Sensorless AC 1HP Drive. Call Now! | Image
Reliance Electric GV-3000 GV3000/SE Sensorless AC 1HP Drive. Call Now! | Image

1V4160

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (4)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (4)
  • Click a star to rate this product
Reliance Electric GV-3000 GV3000/SE Sensorless AC 1HP Drive.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 1V4160 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 1V4160
  • SKU: 1V4160RE
  • Manufacturer: Reliance Electric
  • Series: GV3000 Drives

1V4160 Technical Specifications

Manufacturer Reliance Electric
Series GV3000
Part Number 1V4160
HP 1 HP
Input Voltage 380-460 VAC
Enclosure Type 1/IP20
Keypad/Display Built-In Keypad
Phase 3 Phase
kW 0.75kW
Hz 50/60Hz
Instruction Manual D2-3359 & D2-3360

Product Description

The 1V4160 is a 1HP GV3000/SE Reliance Electric Drive drive. This drive may have been sold by Baldor Reliance or ABB depending on when its original production dates were.

The 1V4160 has the ability to be rated for vector or standard V/Hz regulation. It has a KVA of 2.0 and an input amperage of 2.5 with an output amperage of 2.1. It has a power loss of 60 watts full load. For this drive, it is recommended that a 6A rated fuse be used.

The 1V4160 is surrounded by a NEMA 1 type enclosure. This enclosure is vented and has an access door that allows the user to plug in an RS-232 communications cable without needing to remove the entire enclosure cover. This enclosure is supposed to be only used indoors. If you include the enclosure, this drive is 280.7 mm tall, 222.3 mm wide, 200 mm thick, and weighs 6.3 kg.

The 1V4160 has a keypad located on its faceplate. This keypad has quite a few vital components that help the drive perform functions that include programming and operating the drive. The display on the keypad is equipped with a 4-character, 7-segment LED indicator light. There are 14 single LEDs that can display the drive status and indicate the operating mode status of it. There are keys used for stopping, resetting, and starting the drive.

When mounting the 1V4160, it is possible to attach it to a panel. There are 4 mounting holes on the enclosure that can be used to attach it to the panel. The user should ensure that the bolts are thoroughly tightened so that the drive has a flat mounting surface. It is recommended to use washers under the bolt heads to keep the bolts as tight as possible.

Frequently Asked Questions about 1V4160

What jumpers are located on 1V4160's regulator board?
1V4160 has jumpers J3, J4, J5, J7, J8, J9, and J17 on 1V4160's regulator board. View figure 2.9 in the hardware manual for 1V4160, Manual D2-3360, to see 1V4160's regulator board component locations. The diagram in the manual of the component locations also identifies what each jumper on 1V4160's regulator board is. This figure in the manual applies to all 1-60 HP regulator boards.
How do you set the acceleration time in seconds on 1V4160?
Parameter P.001 is the accel time 1 parameter on 1V4160 and this parameter on 1V4160 sets the acceleration time in seconds on 1V4160. Press the up arrow key on 1V4160 to display parameter P.001. Press the 'enter' key on 1V4160's built-in keypad to display the default setting of parameter P.001, which is default to 20 seconds on 1V4160 and press the up or down arrows to increase or decrease the acceleration time in seconds on this parameter for 1V4160.
How do you know if the fan isn't working on 1V4160?
If the cooling fan has failed on 1V4160, the "OH" fault code error should appear on 1V4160's keypad. This fault code on 1V4160 is a drive overtemperature fault error. To correct this fault on 1V4160, check 1V4160's ambient temperature and minimum clearances around 1V4160.
What are the two manuals for 1V4160?
Manual D2-3359 is the software manual for 1V4160 while Manual D2-3360 is the hardware manual for 1V4160. Each manual identifies 1V4160 specifically and each manual is a Reliance manual for 1V4160 that will help with 1V4160 in various ways.

Repair Services For 1V4160

Type Lead Time Price Action
Repair Service 1-2 weeks $1370

Our highly skilled technicians can repair your 1V4160. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

1V4160 Manuals, White Papers, Data Sheets, and Troubleshooting