Reliance Electric GV-3000 GV3000/SE 15 HP AC Drive.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 15V4150 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 15V4150
  • SKU: 15V4150RE
  • Manufacturer: Reliance Electric
  • Series: GV3000 Drives

15V4150 Technical Specifications

Manufacturer Reliance Electric
Series GV3000
Part Number 15V4150
HP 15 HP
Input Voltage 380-460 VAC
Enclosure Type 1/IP20
Keypad/Display Built-In Keypad
Phase 3 Phase
kW 11.2kW
Hz 50/60Hz
Instruction Manual D2-3339 & D2-3340

Product Description

Reliance Electric manufactures 15V4150, a drive that is part of the GV3000 series. 288.0 mm x 463.0 mm x 223.0 mm x 442.0 mm x 238.0 mm are the dimensions of this GV3000 series drive. The drive weighs 15.9 kg. The recommended power wiring sizes are 6 to 3 AWG. The user supplied mounting bolts and washers must be M8 or M10 (5/16” or ⅜”). The drive includes 4 mounting holes for the mounting hardware.

The drive has a number of parameters. Parameter P.010 is the Terminal Strip Analog Input Gain, a tunable parameter that defaults to 1.000 and has a range of 0.100 to 5.000. Parameter P.012 is the Terminal Strip Analog Output Source, a tunable parameter that defaults to 0 and has a range of 0-3. Parameter P.013 is the Output Relay Configuration, a configurable parameter that defaults to 0 and has a range of 0 to 6. Parameter P.014 is the Trim Reference Source, a configurable parameter that defaults to 0 and has a range of 0 to 9. Parameter P.015 is the Trim Gain Percentage, a tunable parameter that defaults to 0.0 and has a range of -100.0% to +100.0%. Parameter P.016 is the Draw Gain Percentage, a tunable parameter that defaults to 0.0 and has a range of -100.0% to +100.0%. Parameter P.019 is the S-Curve Enable, a configurable parameter that defaults to ON (V/Hz) and has a range of ON and OFF.

Frequently Asked Questions about 15V4150

What is parameter U.003 on 15V4150?
Parameter U.003 on 15V4150 is the motor nameplate base frequency parameter on 15V4150. Press the up arrow on 15V4150's built-in keypad to display parameter U.003. The setting of parameter U.003 determines the maximum speed of 15V4150's motor. This parameter on 15V4150 should only be adjusted by someone qualified to do so. Please ask us for assistance in adjusting this parameter on 15V4150.
What causes a high D-C bus voltage fault on 15V4150?
A high D-C bus voltage fault on 15V4150, fault code error HU, is a fault on 15V4150 that can be caused by two different things. The HU fault can be caused by D-C bus voltage being too high on 15V4150 or the HU fault can be caused by a deceleration time that is too short on 15V4150. This fault on 15V4150 can be easily corrected by cheecking input line voltage on 15V4150, or increasing the deceleration time on 15V4150.
Where can I get help with troubleshooting 15V4150?
Both manuals for 15V4150 provide troubleshooting help. Manual D2-3339, the software manual for 15V4150, has a chapter on troubleshooting using error codes for 15V4150. Chapter 5 in the software manual for 15V4150 is where you'll find this troubleshooting information. The hardware manual for 15V4150, Manual D2-3340, also has a troubleshooting chapter. Chapter 9 in Manual D2-3340 is the troubleshooting chapter in the manual for GV3000 power module drives, which includes 15V4150. If you need further troubleshooting help with 15V4150, contact our experts here at AX.
What is the input KVA on 15V4150?
15V4150 has 20.2 KVA input.

Repair Services For 15V4150

Type Lead Time Price Action
Repair Service 1-2 weeks $1587

Our highly skilled technicians can repair your 15V4150. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More