125FR4042

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (3)
  • Click a star to rate this product
Reliance Electric 125FR4042 460 VAC 125 HP FlexPak 3000 DC Motor Controller

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 125FR4042 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 125FR4042
  • SKU: 125FR4042RE
  • Manufacturer: Reliance Electric
  • Series: FlexPak 3000

125FR4042 Technical Specifications

Manufacturer Reliance Electric
Series FlexPak 3000
Part Number 125FR4042
Input Voltage 460 VAC
HP 125 HP
Hz 50/60 Hz

Product Description

125FR4042 is a drive controller with a horsepower of 125 that is manufactured by Reliance Electric. The following are the Quick Start parameters for this FlexPak 3000 drive. The top speed parameter is code number 011 and the default is 500 RPM. The motor rated armature amps parameter is code number 008 and the default is 8 amps. The motor rated armature volts parameter is code number 009 and the default is 400 volts. The reverse disable parameter is code number 015 and the default is OFF. The feedback select parameter is code number 200 and the default is armature volts. The analog tachometer volts/1000 RPM parameter is code number 203 and the default is 60 V/1000 RPM. The pulse tachometer PPR parameter is code number 207 and the default is 1024 PPR. The pulse tachometer quadrature parameter is code number 208 and the default is ON. The acceleration rate parameter is code number 001 and the default is 5 seconds. The deceleration rate parameter is code number 002 and the default is 5 seconds. The minimum speed parameter is code number 003 and the default is 0 RPM. the maximum speed parameter is code number 004 and the default is 500 RPM. the jog acceleration/deceleration rate parameter is code number 013 and the default is 3 seconds. The jog speed1 parameter is code number 012 and the default is 250 RPM. The positive current limit parameter is code number 005 and the default is 150% FLA. The negative current limit parameter is code number 006 and the default is 150% FLA. The IR Compensation parameter is code number 206 and the default is 0% FLA. The motor hot field amps parameter is code number 510 and the default is 0.01 amps.

Frequently Asked Questions about 125FR4042

What is the rated armature current on the 125FR4042?
The default setting of the Motor Rated Arm Amps parameter, parameter P.008, is 8.0 amps on a 125FR4042. The parameter range on P.008 on a 125FR4042 is 0 to 3000.0 amps.
Where can I find the 125FR4042 user manual?
The FlexPak 3000 Series manual has detailed information on all of the drive models including the 125FR4042. You can find the manual by searching the manual number D2-3375 online. 
What is the 125FR4042's maximum full load current limit?
The 125FR4042 has a full load maximum current limit of 150% per minute and 200% per five seconds. 
What are some user adjustable features the 125FR4042 has?
The 125FR4042 has adjustable speed limits, I/R compensations, and reverse disable on regerative drives which are all user adjustable features. 

Repair Services For 125FR4042

Type Lead Time Price Action
Repair Service 1-2 weeks $4600

Our highly skilled technicians can repair your 125FR4042. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More