About the 10FN4042
10FN4042 is a non-regenerative 460 VAC FlexPak 3000 drive that is manufactured by Reliance Electric.
The TOP SPEED parameter is code #011 and the default is 500 RPM.
The MOTOR RATED ARM AMPS parameter is code #008 and the default is 8 amps.
The MAXIMUM CURRENT parameter is code #007 and the default is 150% FLA.
The REVERSE DISABLE parameter is code #015 and the default is OFF.
The FEEDBACK SELECT parameter is code #200 and the default is the armature voltage.
The ANLG TACH VOLTS/1000 parameter is code #203 and the default is 18V/1000 RPM.
The MOTOR RATED ARM VOLTS is code #009 and the default is 240 volts.
The ACCELERATION RATE is code #001 and the default is 5 seconds.
The DECELERATION RATE is code #002 and the default is 5 seconds.
The MINIMUM SPEED is code #003 and the default is 250 RPM.
The MAXIMUM SPEED is code #004 and the default is 500 RPM.