Automax Data Plus Interface Unit | Image
3 year warranty

Automax Data Plus Interface Unit | Image
Automax Data Plus Interface Unit - Wiring Diagram Image

0-57442-

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.57 (7)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.57 (7)
  • Click a star to rate this product
Automax Data Plus Interface Unit

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 0-57442- to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 0-57442-
  • SKU: 057442RE
  • Manufacturer: Reliance Electric
  • Series: AutoMax PLC

0-57442- Technical Specifications

Manufacturer Reliance Electric
Series AutoMax PLC
Part Number 0-57442-
Product Type Data Highway Plus Interface Module
Instruction Manual J2-3067

Product Description

The 0-57442- unit is a Data Highway Plus Interface Module that Reliance Electric was responsible for designing and producing. This module has been discontinued by the OEM, but we may still have it available. Call to check the availability of this product.

The 0-57442- interface module was designed to provide the user with a direct connection between their AutoMax system and the Allen-Bradley Data Highway Plus network. The 0-57442- interface module can be connected into any slot that is available in an AutoMax system rack that has at least one processor. By doing this, it can communicate with up to four processors that are contained within that rack. Please note that this rack which contains the 0-57442- interface module will appear as a single station instead of multiple ones on the Data Highway Plus network.

Contained within the 0-57442- interface module, there is a microprocessor that is powered with 8 mHz. This microprocessor will share a portion of the dual port memory with the AutoMax rack backplane, making it accessible to both the microprocessor and the AutoMax processors that are connected to the rack. 

Installation for the 0-57442- interface module is easy. To begin, ensure that any and all application tasks are halted and that the rack’s power is completely turned off. Insert the 0-57442- interface module into the rack and secure it into place by using a screwdriver. Next, set the 0-57442- interface module’s station number in octal by utilizing the two thumbwheel switches, which you will be able to locate on the module’s faceplate. After that, be sure to connect the 0-57442- interface module to the Data Highway Plus network. After all of that is done, you will be able to turn the rack back on.

Frequently Asked Questions about 0-57442-

What does the microprocessor on 0-57442- share?
The 8 MHz microprocessor on 0-57442- shares 32K dual port memory with the AutoMax rack backplane.
What registers contain all of the global data on 0-57442-?
Registers 4096-4159 contain all of the global data that can exist on a 0-57442- network. For 0-57442- registers and descriptions, view section 4.1.3 in the manual - Manual J2-3067.
What is the shipping weight of 0-57442-?
0-57442- has a shipping weight of about 2 pounds.
Where can I find the manual for 0-57442-?
We have the manual for 0-57442- available and can send you the 0-57442- manual right away. The manual is Manual J2-3067 and the manual is specific to 0-57442-, being the Data Highway Plus Interface Module Manual for 0-57442-.
  • 0-57442-1
  • 0-57442-1A
  • 0-57442-1B
  • 0-57442-1C
  • 0-57442-1D
  • 0-57442-1E
  • 0-57442-1F
  • 0-57442-1G
  • 0-57442-1H
  • 0-57442-1I
  • 0-57442-1J
  • 0-57442-1K
  • 0-57442-1R
  • 0-57442-2
  • 0-57442-2A
  • 0-57442-2B
  • 0-57442-2C
  • 0-57442-3
  • 0-57442-3A
  • 0-57442-4
  • 0-57442-4A
  • 0-57442-4B
  • 0-57442-4C
  • 0-57442-A
  • 0-57442-B
  • 0-57442-C
  • 0-57442-D
  • 0-57442-E
  • 0-57442-F
  • 0-57442-G
  • 0-57442-H
  • 0-57442-I
  • 0-57442-J
  • 0-57442-K
  • 0-57442-L
  • 0-57442-M
  • 0-57442-N
  • 0-57442-O
  • 0-57442-P
  • 0-57442-Q
  • 0-57442-R
  • 0-57442-S
  • 0-57442-T
  • 0-57442-U
  • 0-57442-V
  • 0-57442-W
  • 0-57442-X
  • 0-57442-Y
  • 0-57442-Z

Repair Services For 0-57442-

Type Lead Time Price Action
Repair Service 1-2 weeks $233

Our highly skilled technicians can repair your 0-57442-. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

0-57442- Manuals, White Papers, Data Sheets, and Troubleshooting