T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Image One
3 year warranty

T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Image 1
T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Image 2

T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
Multilin's T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX is a Transformer Protection System that can employ monitoring features to track data such as hottest point.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX
  • SKU: T60C00HCHF8AH6PM8CP6PUXXMXXGM
  • Manufacturer: GE Multilin
  • Series: UR Series Universal Relays

T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Technical Specifications

# of FlexLogic Lines of Code 512
DCMA Input Impedance 379 Ω ±10%
Event Recording Capacity 1024 events
Installation Category II
Phase Undervoltage Level Accuracy ±0.5% of reading from 10 to 208 V
RS232 Front Port 19.2 kbps, Modbus® RTU
Underfrequency Minimum Signal 0.10 to 1.25 pu in steps of 0.01

Product Description

The T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX is a Transformer Protection System designed by General Electric Multilin. It is capable of monitoring transformer assets through its hottest spot, loss-of-life, and aging factor features. It also boasts a number of safeguarding capabilities, such as sensitive ground fault protection and overexcitation inhibiting. This particular model is a standard horizontal unit and functions in a high power range (125 to 250 V DC, 100 to 240 V at 50/60 Hz V AC). 

General Electric Multilin’s EnerVista UR software program can manage the relay and provides a number of benefits for the T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX. A few of the features include:

  • EnerVista Integrator: This feature assists the relay in successfully integrating into new or existing transformer systems, removing a large portion of the burden from the user and enabling the relay to begin operation more quickly. The tool is capable of installing Multilin drivers, establishing an OPC/DDE server, and automatically retrieving event and waveform data from the system.

  • Viewpoint Monitoring: GE’s ViewPoint Monitoring package offers a holistic HMI package complete with Plug & Play capability. The suite offers system single-line control and monitoring and annunciator alarm screens.

  • Viewpoint Maintenance: The Viewpoint Maintenance tools allow the creation of reports on relay operating status. It also simplifies steps for exporting this data and assists in the cyber-security compliance audit process. Lastly, this tool offers single-click fault data retrieval.

The features streamline user processes and are considerably more efficient than editing setpoints and monitoring system values using the keypad and LCD alone. 

Frequently Asked Questions about T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX

How many protection functions (FlexElements) does the T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX have?
The T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX has sixteen protection functions that are able to be defined by the user and are able to be programmed in order to respond to sequence current, ground current, voltage power, power factor, frequency, or other quantities that are measured by the unit. This capability affords multiple applications such as temperature differentials, over power, low power factor, and overvoltage.
What is the restricted ground fault of the GE Multilin T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Universal Relay Transformer Protection System?
The restricted ground falt feature allows the T60 to provide protection when fault currents are below the detection of transformer differential elements in the neutral point of wye-connected windings. This feature is also known as zero-sequence differential.
What order codes are specified with the T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Universal Relay Transformer Protection System?
The T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX Universal Relay Transformer Protection System does not have any software options included (00). The unit is of the horizontal standard 19 inch mount with a power supply of 125/250 V AC/DC. The double power supply (redundant) is only possible with the horizontal mount, which this unit has. 
What is the user interface used for?
The user interface on the T60 front panel is useful for noting status messages, diagnosis of faults, monitoring, and device configuration. 

Reviews For T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX

Internal Review
(5.0)

The T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX utilizes Multilin’s FlexLogic technology, enabling the relay to execute complex actions through its highly configurable code. The relay runs on a maximum of 1024 lines of FlexLogic code, which is more than enough to run a highly customized and efficient logic system. -AX Control Tech Team

Repair Services For T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX

Type Lead Time Price Action
Repair Service 1-2 weeks $1480

Our highly skilled technicians can repair your T60-C00-HCH-F8A-H6P-M8C-P6P-UXX-MXX. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More