Boasting a bevy of system monitoring and metering capabilities, GE Multilin's G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L acts as a Generator Protection System for medium to large generators, usually those driven by gas, hydraulics, or steam.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L
  • SKU: G60N00ALHF8MH6LM8MP6LU6LW6LGM
  • Manufacturer: GE Multilin
  • Series: UR Series Universal Relays

G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L Technical Specifications

Display Type color graphical back-lit LCD
Generator Unbalance Timer Accuracy ±3% of operate time or ±20 ms, whichever is greater
Neutral Overvoltage Pickup Level 0.004 to 3.000 pu in steps of 0.001
Noise 0 dB
Overvoltage Category II
RS232 Port Protocol 19.2 kbps, Modbus RTU
Volts Per Hertz Reset Delay 0.0 to 1000.0 s in steps of 0.1

Product Description

Boasting a range of I/O options and a bevy of system monitoring and metering capabilities, GE Multilin’s G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L acts as a Generator Protection System for medium to large generators, usually those driven by gas, hydraulics, or steam. It offers a number of Cyber Security measures such as password implementation, and Multilin’s EnerVista UR software program helps compile relevant cyber security data to reduce workload on the user for cyber security audits.

Some of the relay’s communications options include a USB port, an RS232 port (located on the faceplate), an RS485 port, and Ethernet. The relay also has a number of communications-related features, such as LAN redundancy and direct I/O messaging. The G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L’s LAN redundancy feature eliminates the traditional LAN switchover process that results in LAN downtime by enabling the relay to become a dual attached node that uses both the main and redundant network simultaneously to transfer data packets. If one of the networks goes down, at least one of the packets will arrive at its intended destination.

The relay’s scalable hardware provides configurable protection for the most rigorous of systems. The faceplate swings open to allow the installation of additional modules such as Multilin’s Field Ground Protection Module (GPM-F), which can detect ground faults in the field wiring of the generator. Modules can only be replaced with like modules, so users should ensure they are installing modules into the correct location by noting down the slot while removing the original module.

Frequently Asked Questions about G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L

What are the CT/VT and CPU components of the GE Multilin G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L Generator Protection System G60 universal relay?
The GE Multilin G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L serves to provide the user with a universal relay generator protection system G60 UR Series. This G60 contains two 8M CT/VT modules designated at the M__ and the F__ positions in the order code product breakdown. These GE Multilin CT/VT modules have the 8M order code which is a new CT/VT module. These new modules have sensitive ground 4CT/4VT characteristics with enhanced diagnostics. If these are ever used with an older CPU module in the same universal relay then a Hardware mismatch or a display error will show up in the universal relay system. The reverse is also true, where a new CPU module must be used with a new CT/VT in the same universal relay.  If the CT/VT module is new then the universal relay must be characterized by firmware version of 4.0 or higher. 
What is the benefit of a G60 universal relay compared to analog electronic equipment?

Analog electronic equipment first replaced electromechanical equipment; however, both options still had extensive needs for auxiliary equipment and cabling to serve in providing protection, metering, and control functions. Now these digital relays have become comprehensive in their function, such as the G60, reducing the need for much auxiliary equipment and cables.

Reviews For G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L

Internal Review
(5.0)

The variety of features on the front of the faceplate (such as LCD, keypad, and pushbuttons) of the G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L provide convenient access and reference points for users in the relay’s vicinity. -AX Control Tech Team

Repair Services For G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L

Type Lead Time Price Action
Repair Service 1-2 weeks $1399

Our highly skilled technicians can repair your G60-N00-ALH-F8M-H6L-M8M-P6L-U6L-W6L. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More