F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 Image One
3 year warranty

F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 Image 1
F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 Image 2

F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
GE Multilin's F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 is a Multiple Feeder Management Relay that offers a variety of protective functions, such as under/overfrequency protection and phase protection.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67
  • SKU: F35K03HLHF8LH6EM8LP67U6CW67GM
  • Manufacturer: GE Multilin
  • Series: UR Series Universal Relays

F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 Technical Specifications

Auxiliary Overvoltage Level Accuracy ±0.5% of reading from 10 to 208 V
Contact Input Tolerance ±10%
F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 32
Maximum # of Oscillography Records 64
Software EnerVista UR
Thermal Overload Curves IEC 255-8 Curve
Tracking Frequency Range 20 to 70 Hz

Product Description

General Electric Multilin’s F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 is a Multiple Feeder Management System and part of the company’s Universal Relays series. It is capable of monitoring, protecting, and controlling 5-6 feeders, five with busbar voltage measurement and up to six feeders without.

The F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 relay’s LAN redundancy feature delivers redundancy according to PRP-IEC 64239-3, eliminating the dependency on LAN reconfiguration and eliminating the usual switchover time that leaves LAN unavailable. During this function, the device functions as a dual attached node, transmitting packets of data over both redundant and main networks simultaneously; this way, at least one of the data packets will arrive with no time delay even in the event of network failure. 

A variety of safeguarding mechanisms such as breaker reclosing, underfrequency protection, fault diagnostics, remote terminal unit functions, phase protection, and overcurrent and undervoltage protection are provided by the F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67. In addition to safeguarding the multiple feeder system, the F35 can employ metering to gather system parameters such as actual temperature, energy use, and more.

The system runs on a system of highly configurable settings that are most easily created, deleted, and edited on a computer connected to the relay running Multilin’s EnerVista UR software program. Settings can impact everything in the system, ranging from something as minor as disabling pushbutton functions to things as major as when alarms and trips trigger based off system parameters. A few examples of configurable settings include SECURITY, DISPLAY PROPERTIES, OSCILLOGRAPHY, FLEX STATE PARAMETERS, and TELEPROTECTION. 

Frequently Asked Questions about F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67

What does the LAN feature allow a universal relay to do, such as the GE Multilin F35 UR Series Universal Relay F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 Multiple Feeder Management Relay?
The GE Multilin F35 UR Series is a type of universal relay with the model number F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 that functions to provide protection and management for multiple feeders. Even though this specific F35 universal relay has a precise application and is tailored as such, it is still a member of the UR Series of GE Multilin universal relay system products. This means that is functions in generally the same way as other universal relay systems. The LAN ability is the local area network that a universal relay is able to communicate over for coordination with a programming device, an operator interface module, or another universal relay UR device. The universal relay obtains analog or digital input signals and then converts them into local signals within the universal relay by a CPU. This CPU is what coordinates with programming devices or operator interface modules using the LAN. After the CPU, these local signals are converted back to either analog or digital signals to go to control field devices. This basic setup applies to the F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 Multiple Feeder Management Relay and other universal relays.

Reviews For F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67

Internal Review
(5.0)

The F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67 works with the EnerVista software program; its Viewpoint Engineer interface provides drag-and-drop navigation which makes the F35 simple to configure and use. -AX Control Tech Team

Repair Services For F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67

Type Lead Time Price Action
Repair Service 1-2 weeks $1232

Our highly skilled technicians can repair your F35-K03-HLH-F8L-H6E-M8L-P67-U6C-W67. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More