750-P1-G1-S1-HI-A20-R Image One
3 year warranty

750-P1-G1-S1-HI-A20-R Image 1
750-P1-G1-S1-HI-A20-R Image 2
750-P1-G1-S1-HI-A20-R Image 3
750-P1-G1-S1-HI-A20-R Image 4

750-P1-G1-S1-HI-A20-R

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
The 750-P1-G1-S1-HI-A20-R includes a metering function that can determine values such as voltage, frequency, watthour cost, percent of load-to-trip, and running and maximum demand. The relay can use its metering function to trigger an alarm when the breaker maintenance threshold is exceeded.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 750-P1-G1-S1-HI-A20-R to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 750-P1-G1-S1-HI-A20-R
  • SKU: 750P1G1S1HIA20RGM
  • Manufacturer: GE Multilin
  • Series: 750/760 Feeder Management Relay

750-P1-G1-S1-HI-A20-R Technical Specifications

Analog Input Conversion Range 0 to 21 mA
Communications RS232, RS422, RS485 ports
Features Simulation Function, Drawout Construction
Manual 1601-0120-AE
Pollution Degree II
Relay Dimensions 7” W, 6.5” L, 8.5” H
Weight 7.9kg

Product Description

While distribution feeder system management can be a difficult task, General Electric Multilin’s 750-P1-G1-S1-HI-A20-R streamlines the process and extends system life. Equipped with numerous features that protect distribution feeder systems, Multilin’s Feeder Management Relay reduces strain on system components and reduces troubleshooting times through its metering and data logging capabilities.

The relay’s front panel is broken up into approximately four sections: the 40-character liquid crystal display, the keypad, the LEDs, and the RS232 port. The 40-character liquid display is alphanumeric and indicates various system values (configurable by the user) when not in active use. The keypad allows for manual setpoint configuration and general navigation of the relay. The LEDs can indicate when problems arise in the system and also keep users informed on active processes. Finally, the RS232 port allows easy, direct connection between a computer running the EnerVista 750 software and the relay. 

The 750-P1-G1-S1-HI-A20-R includes a metering function that can determine values such as voltage, frequency, watthour cost, percent of load-to-trip, and running and maximum demand. The relay can use its metering function to trigger an alarm when the breaker maintenance threshold is exceeded. Alarm can be indicated through the relay’s twenty aforementioned LEDs.

Additional security measures can be implemented through passcode protection to prevent unauthorized adjustments of setpoints. This password protection works for both manual editing from the front of the relay and editing through the EnerVista 750 program. For manual entering of setpoint configuration, a jumper must be installed on the rear terminal.

Frequently Asked Questions about 750-P1-G1-S1-HI-A20-R

Should the control power match the installed power supply on the GE Feeder Management Relay?
Yes, for the GE Feeder Management Relay to operate properly the control power supplied has to match the installed power supply. If the power supplied doesn't match, the unit could be damaged.
Why is the trip indicator flashing on the GE Feeder Management Relay?
When the trip indicator is flashing on the GE Feeder Management Relay it means that the relay detects a trip and the relay trip is open breaker. When the fault is cleared, the LED will turn off and reset.
How many output relays do the GE Feeder Management Relay have?
The 750-P1-G1-S1-HI-A20-R GE Feeder Management Relay has eight(8) output relays. The 8 output relays have configurable auxiliary relays within 3 through 7. 1 and 2 relays are a trip and a close output relay, while all 8 are self test warning relays.
How major is the A/D Vitual Ground Error on the GE Feeder Management Relay?
The severity for an A/D Vitual Ground Error on the GE Feeder Management Relay for 750-P1-G1-S1-HI-A20-R is a major error. The digital converter has a failure in the analog and the ensurance that data is accurate for the measurement of the systems input is affected by this error.

Reviews For 750-P1-G1-S1-HI-A20-R

Internal Review
(5.0)

This version of the relay is a high-control power unit, making it the best option for distribution feeder systems with high-control power output. -AX Control Tech Team

Repair Services For 750-P1-G1-S1-HI-A20-R

Type Lead Time Price Action
Repair Service 1-2 weeks $1365

Our highly skilled technicians can repair your 750-P1-G1-S1-HI-A20-R. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More