745-W3-P5-G5-HI-A-E Image One
3 year warranty

745-W3-P5-G5-HI-A-E Image 1
745-W3-P5-G5-HI-A-E Image 2
745-W3-P5-G5-HI-A-E Image 3
745-W3-P5-G5-HI-A-E Image 4

745-W3-P5-G5-HI-A-E

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.67 (3)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.67 (3)
  • Click a star to rate this product
The 745-W3-P5-G5-HI-A-E is a high-speed, draw-out transformer protection and management system manufactured by General Electric Multilin. Its windings each function on a phase current input rating and ground current input of 5A.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 745-W3-P5-G5-HI-A-E to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 745-W3-P5-G5-HI-A-E
  • SKU: 745W3P5G5HIAEGM
  • Manufacturer: GE Multilin
  • Series: 745 Transformer Protection System

745-W3-P5-G5-HI-A-E Technical Specifications

Operating Environment Humidity up to 90% non-condensing
Tap Position Range 0 to 500 Ω or 0.5 to 5.0 kΩ
Software Version EnerVista 745
Operating Temperature -40°C (-40°F) to +60°C (140°F)
Ambient Storage Temperature -40°C (-40°F) to +80°C (176°F)
Frequency 50 or 60 Hz nominal
Control Power Range 90 to 300 V DC; 70 to 265 V AC at 48 to 62 Hz
Analog Input Impedence 375 Ω ±10%

Product Description

The 745-W3-P5-G5-HI-A-E is a high-speed, draw-out transformer protection and management system manufactured by General Electric Multilin. Part of the 745 series, this particular model is three winding and includes analog inputs/outputs and an enhanced LCD. Additionally, this model is the high control power version of the series. Its windings each function on a phase current input rating and ground current input of 5A. 

The 745 employs metering technology, eliminating the need for extraneous equipment and connections to the transformer system. It is capable of monitoring and recording voltage, current, power, energy, temperature, and more. These values can be displayed on the enhanced LCD when not in direct use, or alternatively examined through GE’s industry standard EnerVista 745 program. The RS232 or RS422/RS485 ports can both be used to connect computers to the system, or users can purchase a different model that allows Ethernet setup and connection. These parts are demarcated by a “T” in the model number, and they can be found by searching our website or scanning through AX Control’s 745 series page. 

GE Multilin’s 745-W3-P5-G5-HI-A-E reduces costs through its asset monitoring, determining hottest-spot temperature and aging factors to calculate when it is best to replace or perform maintenance on power transformers. Its adaptive capabilities also lower costs by reducing overall strain on the system and alerting users when problems occur within the transformer system.

This relay features neither the loss of life feature or the restricted ground fault feature, though both can be added while in the field according to GE Multilin.

Frequently Asked Questions about 745-W3-P5-G5-HI-A-E

For the Transformer Protection System Multilin 745-W3-P5-G5-Hi-A-E, can this system dress the power requirements of different power systems?
The Multilin 745 systems, and in this case specifically the 745-W3-P5-G5-Hi-A-E transformer managment relay, are designed to handle the differing power requirements of various system configurations. There are unique setpoint groups so that the operator is able to choose which setting is appropriate for the differing protection requirements for a given power system configuration. The 745-W3-P5-G5-Hi-A-E has the option to select from up to four different groups of relay settings.
What phase current input rating does the 745-W3-P5-G5-Hi-A-E Multilin transformer management relay have?
The 745-W3-P5-G5-Hi-A-E Multilin transformer management relay has a phase current input rating that is designated by the P5 alphanumeric code within the part number. In other words, the winding 1, winding 2, and winding 3 are all equal to 5 A. If this code was P1, all the windings would be equal to 1 A, and for more diverse selections (P15), for example, the first winding is equal to 1 A and the second is equal to 5 A. The manual has more specific breakdowns for various P options.
What is the frequency for the transformers of the 745-W3-P5-G5-Hi-A-E Multilin transformer management relay?
The 745-W3-P5-G5-Hi-A-E Multilin transformer management relay is three winding with a frequency of 50 or 60 Hz nominally.

Reviews For 745-W3-P5-G5-HI-A-E

Internal Review
(4.0)

Although this unit is still an excellent choice for transformer management, the power supply is occasionally prone to needing repairs or maintenance. AX Control can help with all repair needs. -AX Control Tech Team

Repair Services For 745-W3-P5-G5-HI-A-E

Type Lead Time Price Action
Repair Service 1-2 weeks $1564

Our highly skilled technicians can repair your 745-W3-P5-G5-HI-A-E. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More