Generator Management Relay 489-P5-HI-A1-E was designed with an Enhanced Display. This relay has lower analog outputs than other models at 0 to 1 milliamperes. The phase current inputs on this model are 5A phase CT secondaries.

AVAILABILITY:

IN STOCK
SHIPS TODAY

Sell Surplus: Have a 489-P5-HI-A1-E to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 489-P5-HI-A1-E
  • SKU: 489P5HIA1EGM
  • Manufacturer: GE Multilin
  • Series: 489 Generator Management Relay

489-P5-HI-A1-E Technical Specifications

Analog Current Input Type Passive
IRIG-B Input Impedence 50 kΩ ±10%
Loss of Excitation Timing Accuracy ±100ms or ± 0.5% of total time
Low Forward Power Block from Online 0 to 15000 s in steps of 1
Max Continuous Phase Voltage Inputs 280 VAC
Neutral Voltage Input VT Secondary 100 VAC at Full-Scale
RTDs 1 to 12 Pickup Hysteresis 2°C
Undervoltage Pickup Accuracy As Per Voltage Inputs

Product Description

One key feature of the 489-P5-HI-A1-E model that makes it a worthwhile investment is that it has an enhanced display, the enhanced display on this specific relay allows for a larger LCD which can help the user immensely. 

The relay is equipped with analog testing output setpoints. These setpoints can be used during the testing or startup of the relay to ensure that all of the analog outputs on the model are performing accurately, if any errors have occurred it could indicate that the model is experiencing difficulties with the analog outputs. It should also be noted that if the attached generator the relay is working with is offline, currents are not being accurately measured, or no alarms or trips are active then the analog outputs can be forced. If the outputs are forced the In-Service indicator on the device will flash to specify that the 489 relay is not operating in protection mode. 

When installing and mounting the 489-P5-HI-A1-E relay the location must be taken into account as the door on the case of the 489 relay must be able to open without any interference to, or from the adjoining equipment. If an interference is possible then a different location is recommended for the mounting as any interference could cause damage to the door. 

Three groups of indicators are available on the 489-P5-HI-A1-E model. These groups are output status, generator status, and 489 status LED indicators. The following indicators are associated with the output status group indicators, 6 service, 5 alarm, 1 trip, and 2, 3, and 4 auxiliary LEDs. 

Reviews For 489-P5-HI-A1-E

Internal Review
(5.0)

A variety of tests are available for this relay to ensure that it is operating correctly, one of the tests that can be performed on this model is the overload curve accuracy test. Information pertaining to this test can be found in the seventh chapter on page twelve. - AX Control Tech Team

Repair Services For 489-P5-HI-A1-E

Type Lead Time Price Action
Repair Service 1-2 weeks $1801

Our highly skilled technicians can repair your 489-P5-HI-A1-E. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More