In Stock
469-P5-LO-A20 Image One
3 year warranty

469-P5-LO-A20 Image 1
469-P5-LO-A20 Image 2
469-P5-LO-A20 Image 3
469-P5-LO-A20 Image 4

469-P5-LO-A20

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.00 (1)
  • Click a star to rate this product
Produced by GE Multilin as part of their 469 series, the 469-P5-LO-A20 is one of the low control power models and functions at a range of 24 to 60 VDC and 20 to 48 VAC at 48 to 62 Hz. The relay is intended to protect and manage motors ranging from medium to large.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 469-P5-LO-A20 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 469-P5-LO-A20
  • SKU: 469P5LOA20GM
  • Manufacturer: GE Multilin
  • Series: 469 Motor Management Relay

469-P5-LO-A20 Technical Specifications

Clock Accuracy ±5 minutes/month
Software EnerVista 469
Fuse Type .5 × 20 mm SLO-BLO HRC Littelfuse, high breaking capacity
Digital Inputs 9 opto-isolated inputs
Analog Current Conversion Range 0 to 21 mA
RTD Sensing Current 5 mA
Display 40-character alphanumeric LCD

Product Description

Produced by GE Multilin as part of their 469 series, the 469-P5-LO-A20 is one of the low control power models and functions at a range of 24 to 60 VDC and 20 to 48 VAC at 48 to 62 Hz. The relay is intended to protect and manage motors ranging from medium to large. 

The 469-P5-LO-A20 setpoint system increases configurability by offering the user a large array of customizable settings that directly affect the functions of the relay and motor system. Inputs can be assigned, time intervals can be adjusted, and data can be reviewed or cleared, among other functions. Setpoints can first be easily established through the relay’s Auto-Configuration feature and later adjusted as users come to understand the system’s needs.

The 469 relay has five pre-assigned digital inputs and four that are assignable, making up a grand total of nine digital inputs. The five that are pre-assigned are consistently functional, while the four digital inputs remain inert until proper assignment is made by the user. Some examples of assignable inputs include the Remote Alarm function, Remote Trip function, and Speed Switch Trip function.

The relay also has four analog output channels that range from 4 to 20mA, demarcated by the “A20” located in the model number. The analog output channels can work with different variables such as power factor, kW demand, and hottest bearing RTD. More information can be found in General Electric’s user manual for the 469, the 1601-0122-AG manual; this resource can be located on AX Control’s website.

Frequently Asked Questions about 469-P5-LO-A20

What should the phase CTs, ground CTs, and motor full load current be set for the GE 469-P5-LO-A20 Relay?
For the GE 469-P5-LO-A20 Relay the phase CTs have to be chosen for the full load current at 50 percent to 100 percent of a primary CT, but with the full load current is 347.5A a 350:5, or 400:5 CT can be picked  and  the 400:5 is standard for the size that is selected. The high resistive grounding systems are senstive to ground detection and are possible with the 50:0.025 CT. Setting the motor full load current to 348A is specified by the other data sheets of the phase current transformers and ground current transformers.
What are the over load pick up and over load curve settings for the GE Motor Management Relay's?
The over load pick up setting should be on the highest service factor of 1.25 x full load current, so that the motor service factor is at 1.15 and if the service factor is unknown, then it should be automatically set to 1.0. This motor has resistance temperature detectors (RTDs) that the relay with be using to protect the over load pick up. For the over load curve to not compromise the protection on the relay, the over load curve should be set at the standard over load curve and to have the most process up time, it will be just below the cool thermal limit. Over load curve 7 is the best fitting for this relay.

Reviews For 469-P5-LO-A20

Internal Review
(5.0)

The 469-P5-LO-A20’s RS232 and RS485 ports provide easy connection to computers running GE Multilin’s EnerVista 469 software program. Its plug and play technology makes this process even easier so that users can begin reviewing data and editing setpoints as quickly as possible. -AX Control Tech Team

Repair Services For 469-P5-LO-A20

Type Lead Time Price Action
Repair Service 1-2 weeks $1982

Our highly skilled technicians can repair your 469-P5-LO-A20. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More