In Stock
369-HI-R-0-0-0 Image One
3 year warranty

369-HI-R-0-0-0 Image 1
369-HI-R-0-0-0 Image 2
369-HI-R-0-0-0 Image 3
369-HI-R-0-0-0 Image 4

369-HI-R-0-0-0

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
GE Multilin's 369-HI-R-0-0-0 Motor Management Relay is designed to control and protect medium to large motors. The 369 includes protection features such as undervoltage auto-restart, reverse power, the starter failure, the kVA demand, the kvar demand, the kW demand, the current demand, the backspin detection, the self test/service, the trip counter, loss of RRTD communications, the broken/open RTD, the short/low temp RTD, the ambient RTD, the acceleration timer, mechanical jam, and more.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 369-HI-R-0-0-0 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 369-HI-R-0-0-0
  • SKU: 369HIR000GM
  • Manufacturer: GE Multilin
  • Series: 369 Motor Management Relay

369-HI-R-0-0-0 Technical Specifications

Communications non-isolated RS232 port, RS485 ports
Differential Switch Time Delay <200 ms
Dimensions approx: 29.6cm H x 10.7cm W x 20.5cm L
Ground Current Input Frequency 20 to 100 Hz
Overvoltage Category II
Power nominal: 20 VA; maximum: 65 VA
Waveform Capture Length 3 buffers containing 16 cycles of all current and voltage channels
Weight approx. 10 lbs

Product Description

369-HI-R-0-0-0 is a motor management relay that is manufactured by GE Multilin. The control power is 50-300 VDC / 40-265 VAC. There are 12 optional RTD inputs for this relay. This unit does not include metering or backspin detection. There is no optional fiber optic port. This relay provides protection and monitoring for 3-phase motors and their associated systems. The 369 can ‘learn’ individual motor parameters and adapt itself to individual applications. In order to improve the protective capabilities of the relay, the user may adjust the motor inrush current, the cooling rates, and/or the acceleration time. If you have any questions about this part or series, please contact AX Control.

Protection features on the relay include the undervoltage auto-restart, reverse power, the starter failure, the kVA demand, the kvar demand, the kW demand, the current demand, the backspin detection, the self test/service, the trip counter, loss of RRTD communications, the broken/open RTD, the short/low temp RTD, the ambient RTD, the acceleration timer, the mechanical jam, the restart block (backspin timer), the start inhibit (thermal capacity available), the thermal capacity, the reactive power, the general switch, the differential switch, the lockout, the over/under frequency, the alarm, the starts per hour / time between starts, the overvoltage protection, the power factor, the overload protection, the ground fault and ground fault backup, the short circuit and backup, the stator RTD, the voltage phase reversal, the current unbalance protection, the bearing RTD, the undercurrent/under power protection, the undervoltage protection, and the speed switch.

Frequently Asked Questions about 369-HI-R-0-0-0

What metering capabilities are present for the Multilin 369-HI-R-0-0-0 GE motor management relay?
The 369-HI-R-0-0-0 Multilin GE will use monitoring of cooling rate values, motor inrush values, and acceleration time to provide protection and monitoring features for three phase motors. As an option during ordering, the optional metering package can be included. This optional feature would be designated by an M code within the part number at the third position. In the case of the 369-HI-R-0-0-0, there is a zero found at the third position. Thus, the 369-HI-R-0-0-0 369 motor management digital relay does not come with the optional metering package. The optional metering package has the additional ability to supply VT inputs for power and voltage. This package is able to meter values of kW, V, PF, Hz, kvar, and MWhrs. The base unit comes with a single analog output. This feature provides the user with three extra outputs (analog), that are configurable in natur
Does the 369-HI-R-0-0-0 Multilin GE have the draw out option feature as present for the 269PLUS Multilin motor management relay systems?
The 369-HI-R-0-0-0 Multilin GE motor management relays and other digital relays of the 369 Multilin series do not come with the ability to be drawn out for bench top or in-case testing. 

Reviews For 369-HI-R-0-0-0

Internal Review
(5.0)

The 369-HI-R-0-0-0 comes with the optional Resistance Temperature Detector (RTD) inputs, allowing users to monitor values such as hottest spot to gain increased insight into their motor system. -AX Control Technicians

Repair Services For 369-HI-R-0-0-0

Type Lead Time Price Action
Repair Service 1-2 weeks $1444

Our highly skilled technicians can repair your 369-HI-R-0-0-0. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More