8440-1858 Image One
3 year warranty

8440-1858 Image 1
8440-1858 Image 2

8440-1858

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 5.00 (1)
  • Click a star to rate this product
Woodward part 8440-1858 easYgen-2000 Genset control. Operates at a main voltage or busbar voltage absolutely cannot operate under both, rated voltage of 480 V.

AVAILABILITY:

CALL FOR AVAILABILITY

Sell Surplus: Have a 8440-1858 to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 8440-1858
  • SKU: 84401858WO
  • Manufacturer: Woodward
  • Series: easYgen-2000 Series

8440-1858 Technical Specifications

Busbar Voltage 0-650 kV
Continuous CAN Bus Insulation Voltage 100 Vac
Frequency Range 10 Hz to 500 Hz
Input Resistance approx. 20 kΩ
Output Current 100 mA at 24 Vdc
Start Counter 0 to 65,535

Product Description

Here at AX Control INC, we offer the Woodward easYgen-2000 series from our new surplus or refurbished secondhand inventory. The 8440-1858 control is made up of nearly sixty terminals and each has a specific usage. Terminals twenty-two through twenty-nine are used as mains busbar voltage, under no circumstances can the busbar voltage and main voltages be measured at the same time with this control. 

Pertaining to the busbar voltage of the control when inputs are being measured with the busbar windings which are three-phase and four-wire, there are specific terminals to be attached and several of the terminals read at different rated voltages and measuring ranges. Terminals twenty-three, twenty-five, twenty-seven, and twenty-nine have a maximum measuring range of 0 to 600 Vac, the rated voltage range will read at 480 V in a range of 131 to 480 V. 

This control can be used with diesel or gasoline engines. The ignition delay of the engine should be in the range of 0-999 seconds but specifically 5 seconds. Before you start the engine you should perform a purging operation. If after there has been an expiration of time and the minimum speed for the ignition has been achieved this indicates that the ignition has been fully energized. Once ignition speed has been achieved then the starter has been separated under many different conditions, the measurement through magnetic pickup has been disengaged and the speed of the ignition has been measured by the generator voltage. 

If you are interested in purchasing control 8440-1858 you can reach our sales team by phone or email.

Reviews For 8440-1858

Internal Review
(4.0)

Good product that works well as intended so long as it's installed correctly. We tested it here and were successful in making sure everything worked and functioned properly. Just make sure whoever installs it has a certified supervisor with them. -AX Control INC. Tech Team.

  • EasyGen-2200-1

Repair Services For 8440-1858

Type Lead Time Price Action
Repair Service 1-2 weeks $2444

Our highly skilled technicians can repair your 8440-1858. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More

8440-1858 Manuals, White Papers, Data Sheets, and Troubleshooting