6MDVN-4P5101 Image One
2 year warranty

6MDVN-4P5101 Image 1
6MDVN-4P5101 Image 2

International

Phone

1-919-372-8413

Domestic (US)

1-800-991-7026

6MDVN-4P5101

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures 4.67 (9) Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.67 (9)
  • Click a star to rate this product


1HP 0.75kW 1 Phase Input 3 Phase Output 230v Drive

New Surplus Factory Package
SKU: 26MD1
3 Year Warranty
New Surplus AX Control Package
SKU: 26MD2
3 Year Warranty
Reconditioned
SKU: 26MD3
3 Year Warranty
Repair
$394
SKU: 26MD4
3 Year Warranty

* Learn More About Product Conditions
* Posted pricing available for website purchases only.

Product Conditions

New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.

New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.

Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.

Product Description

6MDVN-4P5101 is a Reliance Electric 115V, 50/60 Hz, 1-phase drive that is part of the MD60 drive series. This drive has 0.75 kW, a horsepower rating of 1.0, and an output current of 4.5 A. The frame size is B. The output frequency is display parameter d001. The default is read only and the range is 0.0 to the maximum frequency. The commanded frequency is display parameter d002. The default is read only and the range is 0.0 to the maximum frequency. The output current is display parameter d003. The default is read only and the range is 0.00 to the drive rated amps x 2. The output voltage is display parameter d004. The default is read only and the range is 0 to the drive rated volts. The DC bus voltage is display parameter d005. The default is read only and the range is based on the drive rating. The drive status is display parameter d006. The default is read only and the range includes 0 (Condition False) and 1 (Condition True). Fault codes 1-3 are display parameters d007-d009. The defaults are read only and the ranges are F2 to F122. The process display is display parameter d010. The default is read only and the range is 0.00 to 99999. The control source is display parameter d012. The default is read only and the range is 0 to 9. The control input status is display parameter d013. The default is read only and the range includes 0 (Input Present) and 1 (Input Not Present).

6MDVN-4P5101 Manuals, White Papers, Data Sheets, and Troubleshooting

6MDVN-4P5101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDVN-4P5101
HP 1 HP
Input Voltage 230 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
kW 0.75kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Frequently Asked Questions about 6MDVN-4P5101

What is the output current for a MD60 6MDVN-4P5101?
The 6MDVN-4P5101 has an output current of 4.5 amps. 
How big is a 6MDVN-4P5101?
The MD60 6MDVN-4P5101 drive has a B frame size. A 6MDVN-4P5101 is 3.94 by 8.39 inches, with the height dimension including a NEMA 1/IP30 kit. The MD60 Reliance Electric 6MDVN-4P5101 has a shipping weight of 4.9lbs.
How much does it cost to repair my 6MDVN-4P5101?
Call our sales representative to request a repair quote on your 6MDVN-4P5101. For quicker repairs, your repair quote may be higher than average. We cover the entire cost of domestic ground shipping to and from our facility during the repair of your 6MDVN-4P5101. 
Where can I find an instruction manual for a 6MDVN-4P5101?
We are happy to send you the link to the MD60 AC Drive User Manual written by Reliance Electric. The manual provides instructions on how to mount your 6MDVN-4P5101, how to ground your 6MDVN-4P5101, how to install power and control wiring on your 6MDVN-4P5101, and how to successfully install your 6MDVN-4P5101. The MD60 AC Drive User Manual also provides parameter descriptions and fault codes. 
Where are parameters displayed on a 6MDVN-4P5101 MD60 drive?
Parameters are displayed on the 6MDVN-4P5101 drive's built-in keypad. To find out more about the parameters on a 6MDVN-4P5101, read chapter 8 and 9 of the MD60 AC Drive User Manual. 

6MDVN-4P5101 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDVN-4P5101
HP 1 HP
Input Voltage 230 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
kW 0.75kW
Filter/No Filter Not Filtered
Labeling UL Listed, IEC Certified

Product Description

6MDVN-4P5101 is a Reliance Electric 115V, 50/60 Hz, 1-phase drive that is part of the MD60 drive series. This drive has 0.75 kW, a horsepower rating of 1.0, and an output current of 4.5 A. The frame size is B. The output frequency is display parameter d001. The default is read only and the range is 0.0 to the maximum frequency. The commanded frequency is display parameter d002. The default is read only and the range is 0.0 to the maximum frequency. The output current is display parameter d003. The default is read only and the range is 0.00 to the drive rated amps x 2. The output voltage is display parameter d004. The default is read only and the range is 0 to the drive rated volts. The DC bus voltage is display parameter d005. The default is read only and the range is based on the drive rating. The drive status is display parameter d006. The default is read only and the range includes 0 (Condition False) and 1 (Condition True). Fault codes 1-3 are display parameters d007-d009. The defaults are read only and the ranges are F2 to F122. The process display is display parameter d010. The default is read only and the range is 0.00 to 99999. The control source is display parameter d012. The default is read only and the range is 0 to 9. The control input status is display parameter d013. The default is read only and the range includes 0 (Input Present) and 1 (Input Not Present).

6MDVN-4P5101 Manuals, White Papers, Data Sheets, and Troubleshooting

Frequently Asked Questions about 6MDVN-4P5101

What is the output current for a MD60 6MDVN-4P5101?
The 6MDVN-4P5101 has an output current of 4.5 amps. 
How big is a 6MDVN-4P5101?
The MD60 6MDVN-4P5101 drive has a B frame size. A 6MDVN-4P5101 is 3.94 by 8.39 inches, with the height dimension including a NEMA 1/IP30 kit. The MD60 Reliance Electric 6MDVN-4P5101 has a shipping weight of 4.9lbs.
How much does it cost to repair my 6MDVN-4P5101?
Call our sales representative to request a repair quote on your 6MDVN-4P5101. For quicker repairs, your repair quote may be higher than average. We cover the entire cost of domestic ground shipping to and from our facility during the repair of your 6MDVN-4P5101. 
Where can I find an instruction manual for a 6MDVN-4P5101?
We are happy to send you the link to the MD60 AC Drive User Manual written by Reliance Electric. The manual provides instructions on how to mount your 6MDVN-4P5101, how to ground your 6MDVN-4P5101, how to install power and control wiring on your 6MDVN-4P5101, and how to successfully install your 6MDVN-4P5101. The MD60 AC Drive User Manual also provides parameter descriptions and fault codes. 
Where are parameters displayed on a 6MDVN-4P5101 MD60 drive?
Parameters are displayed on the 6MDVN-4P5101 drive's built-in keypad. To find out more about the parameters on a 6MDVN-4P5101, read chapter 8 and 9 of the MD60 AC Drive User Manual.