6MDAN-2P3111
- 4.75 (4)
- Click a star to rate this product
The 6MDAN-2P3111 MD60 230V 1PH 1/2HP Filtered Drive
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Shipping Weight: 5.0 lbs.
Shipping Dimensions: 5" x 3" x 7"
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the 6MDAN-2P3111
6MDAN-2P3111 is a 230 V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is an integral EMC filter. The frame size is A. There are seven LEDs on the drive. When the RUN LED is on (steady red), the drive is running, When the FWD/REV LED is flashing red, the motor has been commanded to change direction, and when its is steady red, it indicates the commanded motor direction.
When the VOLTS/AMPS/HERTZ is steady red, the parameter value units are being indicated. When the PROGRAM LED is steady read, the drive is in program mode and the parameter value can be changed. When the FAULT LED is flashing red, the drive has a fault. When the Pot Status LED is steady green, the potentiometer on the integral keypad is active. When the Start Key Status is steady gream, the Start key on the integral keypad is active, and the Reverse key is also active unless disabled by A095 (Reverse Disable). Some other critical keys in the 6MDAN-2P3111's interface are its:
-
Program key on the keypad that allows the user to enter/exit program mode, scroll through parameter groups, back up on step in the programming menu, or cancel a change to a parameter value
-
Up and Down arrow keys that allow the user to scroll through P and A parameters, increase and decrease the value of a flashing digit, and increase or decrease the internal frequency parameter if in Display Mode
-
Enter key which allows the user to display a P or A parameter, scroll through display parameters, or save a change to a parameter value
-
Potentiometer that allows the user to control the drive speed
-
Start key that allows the user to start the drive
-
Reverse key that allows the user to reverse the direction of the motor
-
Stop key that allows the user to stop the drive if the drive is running or clear a fault if the drive is stopped
6MDAN-2P3111 Technical Specifications
| Manufacturer | Reliance Electric |
| Series | MD60 |
| Part Number | 6MDAN-2P3111 |
| HP | 0.5 HP |
| Input Voltage | 115-230 VAC |
| Enclosure | NEMA 1 or Chassis |
| Hz | 50/60Hz |
| kW | 0.37kW |
| Filter/No Filter | Internal Filter |
| Labeling | UL Listed, IEC Certified |
Frequently Asked Questions about 6MDAN-2P3111
What is the output current for 6MDAN-2P3111?
What is the branch circuit protection fuse rating for a MD60 6MDAN-2P3111?
What does it mean when the FWD/REV LED is flashing red on my 6MDAN-2P3111 drive?
Reviews For 6MDAN-2P3111
Internal Review
(5.0)As stated above, the 6MDAN-2P3111 drive here has only one half of a horsepower, so any potential industrial accidents or voltage mishaps that may occur are significantly lessened. In addition to this, the 6MDAN-2P3111 MD60 Series drive here has a standard A-size frame which should prime it for a repair done through our website here. - AX Control Lead Technician
6MDAN-2P3111 Technical Specifications
| Manufacturer | Reliance Electric |
| Series | MD60 |
| Part Number | 6MDAN-2P3111 |
| HP | 0.5 HP |
| Input Voltage | 115-230 VAC |
| Enclosure | NEMA 1 or Chassis |
| Hz | 50/60Hz |
| kW | 0.37kW |
| Filter/No Filter | Internal Filter |
| Labeling | UL Listed, IEC Certified |
About the 6MDAN-2P3111
6MDAN-2P3111 is a 230 V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is an integral EMC filter. The frame size is A. There are seven LEDs on the drive. When the RUN LED is on (steady red), the drive is running, When the FWD/REV LED is flashing red, the motor has been commanded to change direction, and when its is steady red, it indicates the commanded motor direction.
When the VOLTS/AMPS/HERTZ is steady red, the parameter value units are being indicated. When the PROGRAM LED is steady read, the drive is in program mode and the parameter value can be changed. When the FAULT LED is flashing red, the drive has a fault. When the Pot Status LED is steady green, the potentiometer on the integral keypad is active. When the Start Key Status is steady gream, the Start key on the integral keypad is active, and the Reverse key is also active unless disabled by A095 (Reverse Disable). Some other critical keys in the 6MDAN-2P3111's interface are its:
-
Program key on the keypad that allows the user to enter/exit program mode, scroll through parameter groups, back up on step in the programming menu, or cancel a change to a parameter value
-
Up and Down arrow keys that allow the user to scroll through P and A parameters, increase and decrease the value of a flashing digit, and increase or decrease the internal frequency parameter if in Display Mode
-
Enter key which allows the user to display a P or A parameter, scroll through display parameters, or save a change to a parameter value
-
Potentiometer that allows the user to control the drive speed
-
Start key that allows the user to start the drive
-
Reverse key that allows the user to reverse the direction of the motor
-
Stop key that allows the user to stop the drive if the drive is running or clear a fault if the drive is stopped
Frequently Asked Questions about 6MDAN-2P3111
What is the output current for 6MDAN-2P3111?
What is the branch circuit protection fuse rating for a MD60 6MDAN-2P3111?
What does it mean when the FWD/REV LED is flashing red on my 6MDAN-2P3111 drive?
Reviews For 6MDAN-2P3111
Internal Review
(5.0)As stated above, the 6MDAN-2P3111 drive here has only one half of a horsepower, so any potential industrial accidents or voltage mishaps that may occur are significantly lessened. In addition to this, the 6MDAN-2P3111 MD60 Series drive here has a standard A-size frame which should prime it for a repair done through our website here. - AX Control Lead Technician