In Stock
6MDAN-2P3111 Image One
2 year warranty

6MDAN-2P3111 Image 1
RELIANCE ELECTRIC MD60 230V 1PH 1/2HP W FLTR | Image
6MDAN-2P3111 Image 3

International

Phone

1-919-372-8413

Domestic (US)

1-800-991-7026

6MDAN-2P3111

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures 4.75 (4) Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.75 (4)
  • Click a star to rate this product


RELIANCE ELECTRIC MD60 230V 1PH 1/2HP W FLTR

New Surplus Factory Package
SKU: 7MD1
3 Year Warranty
New Surplus AX Control Package
$745
SKU: 7MD2
3 Year Warranty
Order Before 3PM EST
Rush Available
1 in Stock
Reconditioned
SKU: 7MD3
3 Year Warranty
Repair
$403
SKU: 7MD4
3 Year Warranty

* Learn More About Product Conditions
* Posted pricing available for website purchases only.

Product Conditions

New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.

New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.

Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.

Product Description

6MDAN-2P3111 is a 230 V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is an integral EMC filter. The frame size is A. There are seven LEDs on the drive. When the RUN LED is on (steady red), the drive is running, When the FWD/REV LED is flashing red, the motor has been commanded to change direction, and when its is steady red, it indicates the commanded motor direction. When the VOLTS/AMPS/HERTZ is steady red, the parameter value units are being indicated. When the PROGRAM LED is steady read, the drive is in program mode and the parameter value can be changed. When the FAULT LED is flashing red, the drive has a fault. When the Pot Status LED is steady green, the potentiometer on the integral keypad is active. When the Start Key Status is steady gream, the Start key on the integral keypad is active, and the Reverse key is also active unless disabled by A095 (Reverse Disable).

The Program key on the keypad allows the user to enter/exit program mode, scroll through parameter groups, back up on step in the programming menu, or cancel a change to a parameter value. The Up and Down arrow keys allow the user to scroll through P and A parameters, increase and decrease the value of a flashing digit, and increase or decrease the internal frequency parameter if in Display Mode. The Enter key allows the user to display a P or A parameter, scroll through display parameters, or save a change to a parameter value. The Potentiometer allows the user to control the drive speed. The Start key allows the user to start the drive. The Reverse key allows the user to reverse the direction of the motor. The Stop key allows the user to stop the drive if the drive is running or clear a fault if the drive is stopped.

6MDAN-2P3111 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDAN-2P3111
HP 0.5 HP
Input Voltage 115-230 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
kW 0.37kW
Filter/No Filter Internal Filter
Labeling UL Listed, IEC Certified

Frequently Asked Questions about 6MDAN-2P3111

What is the output current for 6MDAN-2P3111?
The output current for a MD60 6MDAN-2P3111 is 2.3A.
What is the branch circuit protection fuse rating for a MD60 6MDAN-2P3111?
The 6MDAN-2P3111 fuse rating for 6MDAN-2P3111 is a 10. 
What does it mean when the FWD/REV LED is flashing red on my 6MDAN-2P3111 drive?
When the FWD/REV LED is flashing red on a 6MDAN-2P3111 it means that the drive has been commanded to change direction. The flashing red LED on your 6MDAN-2P3111 is indicating actual motor direction while decelerating to zero.

6MDAN-2P3111 Technical Specifications

Manufacturer Reliance Electric
Series MD60
Part Number 6MDAN-2P3111
HP 0.5 HP
Input Voltage 115-230 VAC
Enclosure NEMA 1 or Chassis
Hz 50/60Hz
kW 0.37kW
Filter/No Filter Internal Filter
Labeling UL Listed, IEC Certified

Product Description

6MDAN-2P3111 is a 230 V, 50/60 Hz, 1-phase MD60 Drive that is manufactured by Reliance Electric. The output current is 2.3 A, the horsepower is 0.5 HP, and the output power is 0.37 kW. There is an integral EMC filter. The frame size is A. There are seven LEDs on the drive. When the RUN LED is on (steady red), the drive is running, When the FWD/REV LED is flashing red, the motor has been commanded to change direction, and when its is steady red, it indicates the commanded motor direction. When the VOLTS/AMPS/HERTZ is steady red, the parameter value units are being indicated. When the PROGRAM LED is steady read, the drive is in program mode and the parameter value can be changed. When the FAULT LED is flashing red, the drive has a fault. When the Pot Status LED is steady green, the potentiometer on the integral keypad is active. When the Start Key Status is steady gream, the Start key on the integral keypad is active, and the Reverse key is also active unless disabled by A095 (Reverse Disable).

The Program key on the keypad allows the user to enter/exit program mode, scroll through parameter groups, back up on step in the programming menu, or cancel a change to a parameter value. The Up and Down arrow keys allow the user to scroll through P and A parameters, increase and decrease the value of a flashing digit, and increase or decrease the internal frequency parameter if in Display Mode. The Enter key allows the user to display a P or A parameter, scroll through display parameters, or save a change to a parameter value. The Potentiometer allows the user to control the drive speed. The Start key allows the user to start the drive. The Reverse key allows the user to reverse the direction of the motor. The Stop key allows the user to stop the drive if the drive is running or clear a fault if the drive is stopped.

Frequently Asked Questions about 6MDAN-2P3111

What is the output current for 6MDAN-2P3111?
The output current for a MD60 6MDAN-2P3111 is 2.3A.
What is the branch circuit protection fuse rating for a MD60 6MDAN-2P3111?
The 6MDAN-2P3111 fuse rating for 6MDAN-2P3111 is a 10. 
What does it mean when the FWD/REV LED is flashing red on my 6MDAN-2P3111 drive?
When the FWD/REV LED is flashing red on a 6MDAN-2P3111 it means that the drive has been commanded to change direction. The flashing red LED on your 6MDAN-2P3111 is indicating actual motor direction while decelerating to zero.