❮
❯
D0-05AR
- 4.78 (9)
- Click a star to rate this product
The D0-05AR 8 AC Input 6 Relay Output PLC
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Shipping Weight: 0.6 lbs.
Shipping Dimensions: 16" x 16" x 16"
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the D0-05AR
The DL05 Micro PLC Model D0-05AR has two RS–232C communication ports and 8 AC inputs and 6 relay contact outputs. The D0-05AD features operating modes that are accessed through a switch on the device or are available from a handheld programming device or optional DirectSOFT 5 programming software. The modes enable programming functions. Several important voltage and environmental ratings for the D0-05AR are its:
- external power requirement of 95-240 VAC, 30 VA maximum
- input voltage range of 80-132 VAC, 47-63 Hz
- operating voltage range of 90-120 VAC, 47-63 Hz
- relay output voltage range of 5-264 VAC (47 -63 Hz), 5-30 VDC
- operating voltage range of 6-240 VAC (47-63 Hz), 6-27 VDC
- ambient operating temperature of 32ºF-131ºF (0º to 55ºC)
- ambient humidity of 5 to 95% relative humidity (non-condensing)
Port 1 on the D0-05AR is a 6-pin modular connector that can be connected to a handheld programming device, an operator interface, or other device containing optional programming software, such as DirectSOFT 5. Port 2 is a 6-pin modular connector and it offers RS-232 communications only. The DL05 Micro PLC D0-05AR offers data storage in V-memory in 16-bit registers and advanced internal diagnostics.
D0-05AR Manuals, White Papers, Data Sheets, and Troubleshooting
D0-05AR Technical Specifications
| Manufacturer | Automation Direct |
| Functional Description | D0-05AR 8 AC Input 6 Relay Output PLC |
| Series | DirectLogic 05 |
| Programming Cable | D2–DSCBL |
| Relative Humidity | 5 to 95% (non-condensing) |
| Vibration Rating | MIL STD 810C 514.2 |
| Shock Rating | MIL STD 810C 516.2 |
| AC Input Commons | 4 channels/common x 2 banks |
| Relay Output Commons | 3 channels/common x 2 banks |
Frequently Asked Questions about D0-05AR
Is the D0-05AR large?
What are the Wire Gauge ratings for this D0-05AR?
Reviews For D0-05AR
Internal Review
(5.0)This One 16AWG or two 18AWG, 24AWG minimum DirectLogic 05 product is a MicroPLC with an intuitive and distinct black design best characterized through its vented chassis for prime air circulation. The D0-05AR status indicators so crucial to its diagnostic processes are imbued on its logic side, as is customary for DirectLogic 05 PLCs. Repair or replace through us today. - AX Control Lead Technician
D0-05AR Technical Specifications
| Manufacturer | Automation Direct |
| Functional Description | D0-05AR 8 AC Input 6 Relay Output PLC |
| Series | DirectLogic 05 |
| Programming Cable | D2–DSCBL |
| Relative Humidity | 5 to 95% (non-condensing) |
| Vibration Rating | MIL STD 810C 514.2 |
| Shock Rating | MIL STD 810C 516.2 |
| AC Input Commons | 4 channels/common x 2 banks |
| Relay Output Commons | 3 channels/common x 2 banks |
About the D0-05AR
The DL05 Micro PLC Model D0-05AR has two RS–232C communication ports and 8 AC inputs and 6 relay contact outputs. The D0-05AD features operating modes that are accessed through a switch on the device or are available from a handheld programming device or optional DirectSOFT 5 programming software. The modes enable programming functions. Several important voltage and environmental ratings for the D0-05AR are its:
- external power requirement of 95-240 VAC, 30 VA maximum
- input voltage range of 80-132 VAC, 47-63 Hz
- operating voltage range of 90-120 VAC, 47-63 Hz
- relay output voltage range of 5-264 VAC (47 -63 Hz), 5-30 VDC
- operating voltage range of 6-240 VAC (47-63 Hz), 6-27 VDC
- ambient operating temperature of 32ºF-131ºF (0º to 55ºC)
- ambient humidity of 5 to 95% relative humidity (non-condensing)
Port 1 on the D0-05AR is a 6-pin modular connector that can be connected to a handheld programming device, an operator interface, or other device containing optional programming software, such as DirectSOFT 5. Port 2 is a 6-pin modular connector and it offers RS-232 communications only. The DL05 Micro PLC D0-05AR offers data storage in V-memory in 16-bit registers and advanced internal diagnostics.
D0-05AR Manuals, White Papers, Data Sheets, and Troubleshooting
Frequently Asked Questions about D0-05AR
Is the D0-05AR large?
What are the Wire Gauge ratings for this D0-05AR?
Reviews For D0-05AR
Internal Review
(5.0)This One 16AWG or two 18AWG, 24AWG minimum DirectLogic 05 product is a MicroPLC with an intuitive and distinct black design best characterized through its vented chassis for prime air circulation. The D0-05AR status indicators so crucial to its diagnostic processes are imbued on its logic side, as is customary for DirectLogic 05 PLCs. Repair or replace through us today. - AX Control Lead Technician