Configure Your P442/4 Line Distance Management Relay
GE Vernova P442/4 Line Distance Management Relay
The P442 Full Scheme Distance Relays are used to manage transmission and subtransmission lines. The P442 relays can be used with a number of types of lines. Some of these are tapped lines, series compensated lines, parallel lines, and non-homogeneous lines. The P442 allows for single-phase tripping for distance protection and channel aided DEF protection. The P444 Line Distance Management Relay Series is a range of numerical full scheme distance relays that also protect and manage transmission and subtransmission lines. The P444 relays can be used for both overhead lines and underground cables in both high and extra high voltage systems. These relays are designed for a variety of lines, including lines with multiple zero sequence sources and tapped lines.
The P442 can be used with an optional redundant Ethernet board, which reduces costs and the need for standalone switches. This also reduces the need for wiring, power supply, and maintenance costs. There are a wide range of protective functions that the P442 relays provide. These relays have 3-phase undercurrent protection, thermal overload protection, and current transformer supervision, in addition to a variety of other protection options. The P444 relays contain channel aided scheme logic and supplementary and back up protection. The relays provide total protection to solidly earthed systems, and feature both local and remote communications ports. The local port is provided on the front of the relay, whereas the rear port is designed for remote communications. The P444 supports a variety of protocols, including Modbus, Courier/K-bus, and DNP 3.0 serial or Ethernet.
There are also some self-diagnostic/fault features on the P442 relays. These features include a fault locator and trip circuit and coil supervision. The P442s have both local and remote communications ports. There are 16 digital inputs on the P442 relays, along with 21 output relays. All of these features help the P442 relays monitor, control, and protect a variety of transmission lines.The P444 relays have a range of management and supervisory functions. Some of these are circuit breaker failure protection, power swing blocking, and trip circuit supervision. Trip circuit supervision is performed through the dedicated programmable scheme logic. Both sets of relays record faults, events, and disturbances. The last 5 faults are recorded with information such as indication of faulted phase and fault location. The P444 relays are designed as full scheme distance relays to be used with a variety of lines and cables.
Product Options
Order code selector coming soon. Starting November 2026, customers will be able to build out the exact configuration they need on our website.