The D0-06DR is a DL06 Micro PLC that has 20 Discrete Inputs Points and 16 Discrete Output Points that was manufactured by Automation Direct
* Learn More About Product Conditions
* Posted pricing available for website purchases only.
Shipping Weight: 5.0 lbs.
Shipping Dimensions: 18" x 12" x 12"
Product Conditions
New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.
New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.
Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.
About the D0-06DR
The D0-06DR is a DL06 Micro PLC model from Automation Direct. This PLC can be used to control and monitor different industrial applications and devices. The D0-06DR offers operating modes via a handheld device to enable programming functions.
There are a number of important specifications to know about the D0-06DR before using the model. Some of these specifications are electrical, while other information is more generalized.
- External Input: 100-240 VAC / 50-60 Hz, 40 W maximum.
- Input Voltage Range: 10.8 to 26.4 VDC.
- Operating Voltage (Rated): 12 to 24 VDC.
DC Inputs
- Quantity: 20 DC inputs.
- Arrangement: Five banks of four inputs.
- Common Terminals: One isolated common terminal per bank.
- Configuration: Each bank can be configured as sinking or sourcing inputs.
Relay Outputs
- Quantity: 16 relay contact outputs.
- Arrangement: Four banks of four normally-open relay contacts.
- Common Terminals: Each bank has a common terminal.
- Output Voltage Range:
- 5-264 VAC (47-63 Hz).
- 5-30 VDC.
- Operating Voltage Range:
- 6-240 VAC (47-63 Hz).
- 6-27 VDC.
Communication Ports
- Port 1: One RS–232C communication port (6-pin modular connector).
- Port 2: One multi-function RS232C/RS422/RS485 port (15-pin HD-sub connector).
- Handheld Device Connection: Can connect to a handheld device containing DirectSOFT 5.
Additional Features
- Data Storage: Offers V-memory data storage.
- Diagnostics: Includes diagnostic capabilities.
D0-06DR Manuals, White Papers, Data Sheets, and Troubleshooting
D0-06DR Technical Specifications
| Part Number | D0-06DR |
| Model Type | Programmable Logic Controller |
| Manufacturer | Automation Direct |
| Series | DirectLogic 06 |
| Weight | 1.8 lbs |
| External Input | 100-240 VAC / 50-60 Hz, 40 W max |
| Input Voltage Range | 10.8 to 26.4 VDC |
| Expansion Modules Allowed | 4 |
| Discrete Input Type | Sinking or sourcing |
| Discrete Output Type | Relay |
Frequently Asked Questions about D0-06DR
Which applications should the relay outputs that the D0-06DR has not be used in?
Which communication standards can be met using Port 1 on the D0-06DR?
Reviews For D0-06DR
Internal Review
(5.0)With 20 DC inputs organized into five configurable banks (sinking or sourcing) and 16 relay contact outputs arranged in four banks, the D0-06DR provides extensive control possibilities. It supports wide operating voltage ranges for both inputs (10.8-26.4 VDC) and outputs (5-264 VAC / 5-30 VDC). Connectivity is a highlight, with one RS–232C port and a multi-function RS232C/RS422/RS485 port, facilitating communication with devices like handheld programmers running DirectSOFT 5. The inclusion of V-memory data storage and diagnostics further enhances its utility, making the D0-06DR a reliable and adaptable solution for micro-PLC applications. – AX Control Lead Technician
D0-06DR Technical Specifications
| Part Number | D0-06DR |
| Model Type | Programmable Logic Controller |
| Manufacturer | Automation Direct |
| Series | DirectLogic 06 |
| Weight | 1.8 lbs |
| External Input | 100-240 VAC / 50-60 Hz, 40 W max |
| Input Voltage Range | 10.8 to 26.4 VDC |
| Expansion Modules Allowed | 4 |
| Discrete Input Type | Sinking or sourcing |
| Discrete Output Type | Relay |
About the D0-06DR
The D0-06DR is a DL06 Micro PLC model from Automation Direct. This PLC can be used to control and monitor different industrial applications and devices. The D0-06DR offers operating modes via a handheld device to enable programming functions.
There are a number of important specifications to know about the D0-06DR before using the model. Some of these specifications are electrical, while other information is more generalized.
- External Input: 100-240 VAC / 50-60 Hz, 40 W maximum.
- Input Voltage Range: 10.8 to 26.4 VDC.
- Operating Voltage (Rated): 12 to 24 VDC.
DC Inputs
- Quantity: 20 DC inputs.
- Arrangement: Five banks of four inputs.
- Common Terminals: One isolated common terminal per bank.
- Configuration: Each bank can be configured as sinking or sourcing inputs.
Relay Outputs
- Quantity: 16 relay contact outputs.
- Arrangement: Four banks of four normally-open relay contacts.
- Common Terminals: Each bank has a common terminal.
- Output Voltage Range:
- 5-264 VAC (47-63 Hz).
- 5-30 VDC.
- Operating Voltage Range:
- 6-240 VAC (47-63 Hz).
- 6-27 VDC.
Communication Ports
- Port 1: One RS–232C communication port (6-pin modular connector).
- Port 2: One multi-function RS232C/RS422/RS485 port (15-pin HD-sub connector).
- Handheld Device Connection: Can connect to a handheld device containing DirectSOFT 5.
Additional Features
- Data Storage: Offers V-memory data storage.
- Diagnostics: Includes diagnostic capabilities.
D0-06DR Manuals, White Papers, Data Sheets, and Troubleshooting
Frequently Asked Questions about D0-06DR
Which applications should the relay outputs that the D0-06DR has not be used in?
Which communication standards can be met using Port 1 on the D0-06DR?
Reviews For D0-06DR
Internal Review
(5.0)With 20 DC inputs organized into five configurable banks (sinking or sourcing) and 16 relay contact outputs arranged in four banks, the D0-06DR provides extensive control possibilities. It supports wide operating voltage ranges for both inputs (10.8-26.4 VDC) and outputs (5-264 VAC / 5-30 VDC). Connectivity is a highlight, with one RS–232C port and a multi-function RS232C/RS422/RS485 port, facilitating communication with devices like handheld programmers running DirectSOFT 5. The inclusion of V-memory data storage and diagnostics further enhances its utility, making the D0-06DR a reliable and adaptable solution for micro-PLC applications. – AX Control Lead Technician