D0-06DR

    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures 4.83 (6) Click a star to rate this product
    Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures Varying star amount pictures
  • 4.83 (6)
  • Click a star to rate this product


The D0-06DR is a DL06 Micro PLC that has 20 Discrete Inputs Points and 16 Discrete Output Points that was manufactured by Automation Direct

New Surplus Factory Package
SKU: 8DI1
3 Year Warranty:
New Surplus AX Control Package
SKU: 8DI2
3 Year Warranty:
Reconditioned
$650
SKU: 8DI3
3 Year Warranty:
Order Before 3PM EST
Rush Available
1 in Stock
Repair
$299
SKU: 8DI4
3 Year Warranty:

* Learn More About Product Conditions
* Posted pricing available for website purchases only.

  Shipping Weight: 5.0 lbs.

  Shipping Dimensions: 18" x 12" x 12"

Product Conditions

New Surplus Factory Package: A completely unused product that is in the original factory package. The package may have been opened for the purpose of pictures, but the product has never been used or installed.

New Surplus AX Control Package: A completely unused product that has been removed from the original factory package. Often due to shelf wear or previous shipping, the factory package is not adequate and must be replaced with an ideal AX Control product package.

Reconditioned: All products that qualify as reconditioned have completed AX Control's thorough and detailed QA process and meet the requirements of excellent working condition and excellent cosmetic condition.

About the D0-06DR

The D0-06DR is a DL06 Micro PLC model from Automation Direct. This PLC can be used to control and monitor different industrial applications and devices. The D0-06DR offers operating modes via a handheld device to enable programming functions.

There are a number of important specifications to know about the D0-06DR before using the model. Some of these specifications are electrical, while other information is more generalized. 

  • External Input: 100-240 VAC / 50-60 Hz, 40 W maximum.
  • Input Voltage Range: 10.8 to 26.4 VDC.
  • Operating Voltage (Rated): 12 to 24 VDC.

DC Inputs
  • Quantity: 20 DC inputs.
  • Arrangement: Five banks of four inputs.
  • Common Terminals: One isolated common terminal per bank.
  • Configuration: Each bank can be configured as sinking or sourcing inputs.

Relay Outputs
  • Quantity: 16 relay contact outputs.
  • Arrangement: Four banks of four normally-open relay contacts.
  • Common Terminals: Each bank has a common terminal.
  • Output Voltage Range:
    • 5-264 VAC (47-63 Hz).
    • 5-30 VDC.
  • Operating Voltage Range:
    • 6-240 VAC (47-63 Hz).
    • 6-27 VDC.

Communication Ports
  • Port 1: One RS–232C communication port (6-pin modular connector).
  • Port 2: One multi-function RS232C/RS422/RS485 port (15-pin HD-sub connector).
  • Handheld Device Connection: Can connect to a handheld device containing DirectSOFT 5.

Additional Features
  • Data Storage: Offers V-memory data storage.
  • Diagnostics: Includes diagnostic capabilities.

D0-06DR Manuals, White Papers, Data Sheets, and Troubleshooting

D0-06DR Technical Specifications

Part Number D0-06DR
Model Type Programmable Logic Controller
Manufacturer Automation Direct
Series DirectLogic 06
Weight 1.8 lbs
External Input 100-240 VAC / 50-60 Hz, 40 W max
Input Voltage Range 10.8 to 26.4 VDC
Expansion Modules Allowed 4
Discrete Input Type Sinking or sourcing
Discrete Output Type Relay

Frequently Asked Questions about D0-06DR

Which applications should the relay outputs that the D0-06DR has not be used in?

These relay outputs should not be used in applications that need to be switched at high speed and duty cycle. The relays should also not be used in applications that require currents under 10 mA. 

Which communication standards can be met using Port 1 on the D0-06DR?

Port 1 on the D0-06DR can meet K-Sequence (Slave), MODBUS (Slave), and DirectNET (Slave) standards. 

Reviews For D0-06DR

Internal Review
(5.0)

With 20 DC inputs organized into five configurable banks (sinking or sourcing) and 16 relay contact outputs arranged in four banks, the D0-06DR provides extensive control possibilities. It supports wide operating voltage ranges for both inputs (10.8-26.4 VDC) and outputs (5-264 VAC / 5-30 VDC). Connectivity is a highlight, with one RS–232C port and a multi-function RS232C/RS422/RS485 port, facilitating communication with devices like handheld programmers running DirectSOFT 5. The inclusion of V-memory data storage and diagnostics further enhances its utility, making the D0-06DR a reliable and adaptable solution for micro-PLC applications. – AX Control Lead Technician

D0-06DR Technical Specifications

Part Number D0-06DR
Model Type Programmable Logic Controller
Manufacturer Automation Direct
Series DirectLogic 06
Weight 1.8 lbs
External Input 100-240 VAC / 50-60 Hz, 40 W max
Input Voltage Range 10.8 to 26.4 VDC
Expansion Modules Allowed 4
Discrete Input Type Sinking or sourcing
Discrete Output Type Relay

About the D0-06DR

The D0-06DR is a DL06 Micro PLC model from Automation Direct. This PLC can be used to control and monitor different industrial applications and devices. The D0-06DR offers operating modes via a handheld device to enable programming functions.

There are a number of important specifications to know about the D0-06DR before using the model. Some of these specifications are electrical, while other information is more generalized. 

  • External Input: 100-240 VAC / 50-60 Hz, 40 W maximum.
  • Input Voltage Range: 10.8 to 26.4 VDC.
  • Operating Voltage (Rated): 12 to 24 VDC.

DC Inputs
  • Quantity: 20 DC inputs.
  • Arrangement: Five banks of four inputs.
  • Common Terminals: One isolated common terminal per bank.
  • Configuration: Each bank can be configured as sinking or sourcing inputs.

Relay Outputs
  • Quantity: 16 relay contact outputs.
  • Arrangement: Four banks of four normally-open relay contacts.
  • Common Terminals: Each bank has a common terminal.
  • Output Voltage Range:
    • 5-264 VAC (47-63 Hz).
    • 5-30 VDC.
  • Operating Voltage Range:
    • 6-240 VAC (47-63 Hz).
    • 6-27 VDC.

Communication Ports
  • Port 1: One RS–232C communication port (6-pin modular connector).
  • Port 2: One multi-function RS232C/RS422/RS485 port (15-pin HD-sub connector).
  • Handheld Device Connection: Can connect to a handheld device containing DirectSOFT 5.

Additional Features
  • Data Storage: Offers V-memory data storage.
  • Diagnostics: Includes diagnostic capabilities.

D0-06DR Manuals, White Papers, Data Sheets, and Troubleshooting

Frequently Asked Questions about D0-06DR

Which applications should the relay outputs that the D0-06DR has not be used in?

These relay outputs should not be used in applications that need to be switched at high speed and duty cycle. The relays should also not be used in applications that require currents under 10 mA. 

Which communication standards can be met using Port 1 on the D0-06DR?

Port 1 on the D0-06DR can meet K-Sequence (Slave), MODBUS (Slave), and DirectNET (Slave) standards. 

Reviews For D0-06DR

Internal Review
(5.0)

With 20 DC inputs organized into five configurable banks (sinking or sourcing) and 16 relay contact outputs arranged in four banks, the D0-06DR provides extensive control possibilities. It supports wide operating voltage ranges for both inputs (10.8-26.4 VDC) and outputs (5-264 VAC / 5-30 VDC). Connectivity is a highlight, with one RS–232C port and a multi-function RS232C/RS422/RS485 port, facilitating communication with devices like handheld programmers running DirectSOFT 5. The inclusion of V-memory data storage and diagnostics further enhances its utility, making the D0-06DR a reliable and adaptable solution for micro-PLC applications. – AX Control Lead Technician