{"id":171,"date":"2020-06-05T19:04:57","date_gmt":"2020-06-05T19:04:57","guid":{"rendered":"https:\/\/www.axcontrol.com\/blog\/?p=171"},"modified":"2021-03-17T14:30:24","modified_gmt":"2021-03-17T14:30:24","slug":"symax-class-8020-fault-codes","status":"publish","type":"post","link":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/","title":{"rendered":"Symax Class 8020 Fault Codes"},"content":{"rendered":"\n<p>Check out our list of <a href=\"https:\/\/www.axcontrol.com\/automation\/square-d\/symax-class-8020\">Schneider Square D SyMax Class 8020<\/a> fault codes. <\/p>\n\n\n\n<p>We offer these codes for those who would like to have more information about typical machine errors that may occur on your current equipment. Feel free to print out this list for quick reference. And if you need us,  remember our team is here to assist with fast and professional repairs.  <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>SyMax Class 8020 Model 300<\/strong><\/h3>\n\n\n\n<p>The Symax Model 300 error codes will display on a connected CRT screen.  <\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter\"><table><tbody><tr><td>Error code<\/td><td> Description<br><\/td><\/tr><tr><td>01<\/td><td>Illegal protocol opcode, the SY\/MAX device does not recognize the instruction<\/td><\/tr><tr><td>02<\/td><td>Illegal intermediate code format.<\/td><\/tr><tr><td>03<\/td><td>An illegal address has been attempted.SY\/MAX device does not contain the requested register(s).<\/td><\/tr><tr><td>04<\/td><td>Illegal rack addressing has been attempted.<br>Attempt was made to incorrectly edit rack addressing<\/td><\/tr><tr><td>05<\/td><td>1. An instruction has been attempted which is not supported in this type processor<br>(Example: square root calculation attempted in Model 300 processor.)<br>&nbsp;<br>2. Incorrect mode set for NIM port connected to a processor (receiving device). Mode set for 8881 mode or peripheral mode.<br>&nbsp;<br>3. In a Nel-to-Net link, the two NIMs have different address settings (on thumb-wheels), or link is between &#8216;0&#8217; port on one and &#8216;l&#8217; port on the other.<\/td><\/tr><tr><td>06<\/td><td>Unable to find the searched-for item. <\/td><\/tr><tr><td>07<\/td><td>An attempt has been made to alter data in a protected register<\/td><\/tr><tr><td>08<\/td><td>An attempt has been made to access protected memory<\/td><\/tr><tr><td>09<\/td><td>An attempt has been made to alter data in a READ ONLY register or a register containing external inputs<\/td><\/tr><tr><td>10<\/td><td>An attempt has been made to exceed memory limitations<\/td><\/tr><tr><td>11<\/td><td>Communication Error. Sy\/Max Device went into an overflow condition<\/td><\/tr><tr><td>12<\/td><td>Illegal CPU rack addressing. Attempted rack address is incompatible with processor hardware<\/td><\/tr><tr><td>13<\/td><td>Communications error (link error.) <\/td><\/tr><tr><td>14<\/td><td>Operation not allowed to run. <\/td><\/tr><tr><td>15<\/td><td>Communications overflow. <\/td><\/tr><tr><td>16<\/td><td>The register count in a communication rung is too large for the processor.<\/td><\/tr><tr><td>17<\/td><td>Unable to establish communications to remote Sy\/Max Device. <\/td><\/tr><tr><td>18<\/td><td>The rung number used is not allowed<\/td><\/tr><tr><td>19<\/td><td>An illegal READ parameter has been assigned<\/td><\/tr><tr><td>20<\/td><td>Channel number in a communication rung is too large for the processor. <\/td><\/tr><\/tbody><\/table><figcaption>The first 20 error codes on a Model 300 <\/figcaption><\/figure>\n\n\n\n<!--more-->\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img data-attachment-id=\"1219\" data-permalink=\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/8020-scp-401\/\" data-orig-file=\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401.jpg\" data-orig-size=\"329,700\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"8020-scp-401\" data-image-description=\"&lt;p&gt;Synax class 8020 product and series can be bought from ax control&lt;\/p&gt;\n\" data-image-caption=\"\" data-medium-file=\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401-141x300.jpg\" data-large-file=\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401.jpg\" decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401.jpg\" alt=\"SyMax Class 8020 Processor.  Many available in AX Control Stock. \" class=\"wp-image-1219\" width=\"250\" height=\"531\" srcset=\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401.jpg 329w, https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401-141x300.jpg 141w\" sizes=\"(max-width: 250px) 85vw, 250px\" \/><figcaption><a href=\"https:\/\/www.axcontrol.com\/automation\/square-d\/symax-class-8020\/8020-SCP-401\">SCP-401 Module<\/a> from SyMax <\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">SyMax 8020 Model 400<\/h3>\n\n\n\n<p>The Symax Model 400 makes use of an enhanced print rung format allowing the user to input ASCII-coded data.   Error codes typically appear within the Status Register.<\/p>\n\n\n\n<figure class=\"wp-block-table aligncenter\"><table><tbody><tr><td><strong>Error Number<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>11<\/td><td>The model is not capable of properly handle incoming <br>characters due to demands from other interrupts<\/td><\/tr><tr><td>13<\/td><td>Parity error<\/td><\/tr><tr><td>15<\/td><td>Framing error, typically caused by word structure issues or <br>baud rate<\/td><\/tr><tr><td>17<\/td><td>Termination occurred before full ASCII string was received. <br>The results from the CPU going to halt, or bit 16 of Register<br>8099\/8100 being set.  If the latter, the buffers in line for ASCII <br>input are cleared<\/td><\/tr><tr><td>19<\/td><td>Buffer overflow.  The 256 character buffer was filled before<br>the terminating character was received. <\/td><\/tr><\/tbody><\/table><figcaption>Most common errors on a Model 400. <\/figcaption><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p class=\"has-text-align-center\">AX Control offers fast shipping of industrial automation parts to customers around the globe.  Let us know what we can help you with. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Check out our list of Schneider Square D SyMax Class 8020 fault codes. We offer these codes for those who would like to have more information about typical machine errors that may occur on your current equipment. Feel free to print out this list for quick reference. And if you need us, remember our team &hellip; <a href=\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Symax Class 8020 Fault Codes&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false},"categories":[10],"tags":[223,224,84,222],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Symax Class 8020 Fault Codes - AX Control, Inc.<\/title>\n<meta name=\"description\" content=\"Need Fault codes for your SyMax Class 8020 processor? Here are a few of the most common fault codes available for your use.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Symax Class 8020 Fault Codes - AX Control, Inc.\" \/>\n<meta property=\"og:description\" content=\"Need Fault codes for your SyMax Class 8020 processor? Here are a few of the most common fault codes available for your use.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\" \/>\n<meta property=\"og:site_name\" content=\"AX Control, Inc.\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-05T19:04:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-03-17T14:30:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401.jpg\" \/>\n<meta name=\"author\" content=\"axcontrol\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"axcontrol\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\"},\"author\":{\"name\":\"axcontrol\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#\/schema\/person\/b19681ba5b3316e7f3357bba95aa697a\"},\"headline\":\"Symax Class 8020 Fault Codes\",\"datePublished\":\"2020-06-05T19:04:57+00:00\",\"dateModified\":\"2021-03-17T14:30:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\"},\"wordCount\":481,\"publisher\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#organization\"},\"keywords\":[\"Fault Tags\",\"Programmable controllers\",\"Square D\",\"SyMax\"],\"articleSection\":[\"Manufacturing\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\",\"url\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\",\"name\":\"Symax Class 8020 Fault Codes - AX Control, Inc.\",\"isPartOf\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#website\"},\"datePublished\":\"2020-06-05T19:04:57+00:00\",\"dateModified\":\"2021-03-17T14:30:24+00:00\",\"description\":\"Need Fault codes for your SyMax Class 8020 processor? Here are a few of the most common fault codes available for your use.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.axcontrol.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Symax Class 8020 Fault Codes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#website\",\"url\":\"https:\/\/www.axcontrol.com\/blog\/\",\"name\":\"AX Control, Inc.\",\"description\":\"A Global Industrial Automation Supplier\",\"publisher\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.axcontrol.com\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#organization\",\"name\":\"AX Control, Inc\",\"url\":\"https:\/\/www.axcontrol.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2019\/12\/image001.png\",\"contentUrl\":\"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2019\/12\/image001.png\",\"width\":200,\"height\":114,\"caption\":\"AX Control, Inc\"},\"image\":{\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/3575940\/\",\"https:\/\/www.pinterest.com\/axcontrol\/\",\"https:\/\/www.youtube.com\/c\/Axcontrolinc\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#\/schema\/person\/b19681ba5b3316e7f3357bba95aa697a\",\"name\":\"axcontrol\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.axcontrol.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/153a58f084a16e17f087b0091053ab6b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/153a58f084a16e17f087b0091053ab6b?s=96&d=mm&r=g\",\"caption\":\"axcontrol\"},\"url\":\"https:\/\/www.axcontrol.com\/blog\/author\/axcontrol\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Symax Class 8020 Fault Codes - AX Control, Inc.","description":"Need Fault codes for your SyMax Class 8020 processor? Here are a few of the most common fault codes available for your use.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/","og_locale":"en_US","og_type":"article","og_title":"Symax Class 8020 Fault Codes - AX Control, Inc.","og_description":"Need Fault codes for your SyMax Class 8020 processor? Here are a few of the most common fault codes available for your use.","og_url":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/","og_site_name":"AX Control, Inc.","article_published_time":"2020-06-05T19:04:57+00:00","article_modified_time":"2021-03-17T14:30:24+00:00","og_image":[{"url":"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/03\/8020-scp-401.jpg"}],"author":"axcontrol","twitter_card":"summary_large_image","twitter_misc":{"Written by":"axcontrol","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/#article","isPartOf":{"@id":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/"},"author":{"name":"axcontrol","@id":"https:\/\/www.axcontrol.com\/blog\/#\/schema\/person\/b19681ba5b3316e7f3357bba95aa697a"},"headline":"Symax Class 8020 Fault Codes","datePublished":"2020-06-05T19:04:57+00:00","dateModified":"2021-03-17T14:30:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/"},"wordCount":481,"publisher":{"@id":"https:\/\/www.axcontrol.com\/blog\/#organization"},"keywords":["Fault Tags","Programmable controllers","Square D","SyMax"],"articleSection":["Manufacturing"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/","url":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/","name":"Symax Class 8020 Fault Codes - AX Control, Inc.","isPartOf":{"@id":"https:\/\/www.axcontrol.com\/blog\/#website"},"datePublished":"2020-06-05T19:04:57+00:00","dateModified":"2021-03-17T14:30:24+00:00","description":"Need Fault codes for your SyMax Class 8020 processor? Here are a few of the most common fault codes available for your use.","breadcrumb":{"@id":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.axcontrol.com\/blog\/2020\/symax-class-8020-fault-codes\/05\/06\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.axcontrol.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Symax Class 8020 Fault Codes"}]},{"@type":"WebSite","@id":"https:\/\/www.axcontrol.com\/blog\/#website","url":"https:\/\/www.axcontrol.com\/blog\/","name":"AX Control, Inc.","description":"A Global Industrial Automation Supplier","publisher":{"@id":"https:\/\/www.axcontrol.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.axcontrol.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.axcontrol.com\/blog\/#organization","name":"AX Control, Inc","url":"https:\/\/www.axcontrol.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.axcontrol.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2019\/12\/image001.png","contentUrl":"https:\/\/www.axcontrol.com\/blog\/wp-content\/uploads\/2019\/12\/image001.png","width":200,"height":114,"caption":"AX Control, Inc"},"image":{"@id":"https:\/\/www.axcontrol.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/3575940\/","https:\/\/www.pinterest.com\/axcontrol\/","https:\/\/www.youtube.com\/c\/Axcontrolinc\/"]},{"@type":"Person","@id":"https:\/\/www.axcontrol.com\/blog\/#\/schema\/person\/b19681ba5b3316e7f3357bba95aa697a","name":"axcontrol","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.axcontrol.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/153a58f084a16e17f087b0091053ab6b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/153a58f084a16e17f087b0091053ab6b?s=96&d=mm&r=g","caption":"axcontrol"},"url":"https:\/\/www.axcontrol.com\/blog\/author\/axcontrol\/"}]}},"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_likes_enabled":false,"jetpack_shortlink":"https:\/\/wp.me\/pbxqch-2L","jetpack-related-posts":[{"id":1589,"url":"https:\/\/www.axcontrol.com\/blog\/2021\/circuit-board-reference-designators-faqs\/24\/08\/","url_meta":{"origin":171,"position":0},"title":"Circuit Board Reference Designators: FAQs","date":"August 24, 2021","format":false,"excerpt":"Circuit board reference designators help identify mounted parts on this GE Mark VI PCB. The board has a number of resistors (R), capacitors (C), and integrated circuits (U). What do you know about circuit board reference designators? If you've worked with printed circuit boards (PCBs) at all, you've noticed the\u2026","rel":"","context":"In &quot;Circuit Boards&quot;","img":{"alt_text":"IS200KTURH1AAA_1","src":"https:\/\/i0.wp.com\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/08\/IS200KTURH1AAA_1-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":2546,"url":"https:\/\/www.axcontrol.com\/blog\/2022\/electric-motor-protection-relays-explained\/01\/12\/","url_meta":{"origin":171,"position":1},"title":"Electric Motor Protection Relays Explained","date":"December 1, 2022","format":false,"excerpt":"Single phasing, Earth faults, and short circuits are just a few potential points of failure in motors. Electric motor protection relays can help.","rel":"","context":"In &quot;Electronics&quot;","img":{"alt_text":"Electric Motor Protection Relays Explained","src":"https:\/\/i0.wp.com\/www.axcontrol.com\/blog\/wp-content\/uploads\/2022\/12\/DQdSWoqKWIEAekXBr1ANex0NRmX82DFy1669147977.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":2589,"url":"https:\/\/www.axcontrol.com\/blog\/2023\/7-common-types-of-transformer-protection-systems\/10\/02\/","url_meta":{"origin":171,"position":2},"title":"7 Common Types of Transformer Protection Systems","date":"February 10, 2023","format":false,"excerpt":"Transformers are well-protected against faults, but they can still happen and cause big headaches. Read on to learn about transformer protection systems.","rel":"","context":"In &quot;Electronics&quot;","img":{"alt_text":"7 Common Types of Transformer Protection Systems","src":"https:\/\/i0.wp.com\/www.axcontrol.com\/blog\/wp-content\/uploads\/2023\/02\/eN1q4qWtpyhOyRoeczDuIEWboJsHK68y1675887248.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":656,"url":"https:\/\/www.axcontrol.com\/blog\/2020\/faqs-about-ge-multilin\/13\/03\/","url_meta":{"origin":171,"position":3},"title":"GE Multilin: Frequently Asked Questions","date":"March 13, 2020","format":false,"excerpt":"GE Multilin has been around since 1995. This part of General Electric focuses on industrial controls and manufacturing relays. This includes flexible process bus solutions and dual and multi-feeder protection for industrial applications. It also includes integrated motor protection for medium\/large induction and synchronous motors. GE Multilin 850 Feeder Protection\u2026","rel":"","context":"In &quot;Education&quot;","img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":890,"url":"https:\/\/www.axcontrol.com\/blog\/2020\/what-is-machine-learning\/26\/08\/","url_meta":{"origin":171,"position":4},"title":"What is Machine Learning?","date":"August 26, 2020","format":false,"excerpt":"What is Machine Learning, Simply? Machine learning, or rather the idea machines can learn to 'do' without an explicit set of instructions (programming), has been the basis of many movies where humans end up getting the short end of the deal. But is machine learning truly that dire? Unlikely. Machine\u2026","rel":"","context":"In &quot;AI and Machine Learning&quot;","img":{"alt_text":"development codes. This represents the \"What is Machine Learning\" question.","src":"https:\/\/i0.wp.com\/www.axcontrol.com\/blog\/wp-content\/uploads\/2020\/08\/pexels-photo-1936299.jpeg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":504,"url":"https:\/\/www.axcontrol.com\/blog\/2020\/what-is-a-printed-circuit-board\/12\/02\/","url_meta":{"origin":171,"position":5},"title":"Printed Circuit Board Basics","date":"February 12, 2020","format":false,"excerpt":"Learn about PCBs, how they work, and how to read them.","rel":"","context":"In &quot;Circuit Boards&quot;","img":{"alt_text":"printed-circuit-board-4083582_1280","src":"https:\/\/i0.wp.com\/www.axcontrol.com\/blog\/wp-content\/uploads\/2021\/04\/printed-circuit-board-4083582_1280.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"_links":{"self":[{"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/posts\/171"}],"collection":[{"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/comments?post=171"}],"version-history":[{"count":7,"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/posts\/171\/revisions"}],"predecessor-version":[{"id":1220,"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/posts\/171\/revisions\/1220"}],"wp:attachment":[{"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/media?parent=171"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/categories?post=171"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.axcontrol.com\/blog\/wp-json\/wp\/v2\/tags?post=171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}