General Electric Multilin's 760-P5-G5-D5-HI-A1-R Feeder Distribution Management Relay utilizes both the Motorola 68332 32-bit microprocessor and the Grid Connect DSTni-LX Turbo 186 16-bit microprocessor to control and safeguard the assigned system.

AVAILABILITY:

IN STOCK
SHIPS IN 3-5 DAYS

Sell Surplus: Have a 760-P5-G5-D5-HI-A1-R to sell? Sell Now
Exchange Credit: Learn more about our exchange credit program
  • Part Number: 760-P5-G5-D5-HI-A1-R
  • SKU: 760P5G5D5HIA1RGM
  • Manufacturer: GE Multilin
  • Series: 750/760 Feeder Management Relay

760-P5-G5-D5-HI-A1-R Technical Specifications

Analog Input Impedance 375 Ω ± 10%
Communications RS232, RS422, RS485 ports
Operating Environment Humidity up to 90% non condensing
Overload Withstand 1 second at 80 x rated current, continuous at 3 x rated current
Pollution Degree II
Relay Dimensions approx. 18cm W, 16.5cm L, 21.5cm H
Weight approx. 18lbs

Product Description

As a a multiprocessor unit, General Electric Multilin’s 760-P5-G5-D5-HI-A1-R Feeder Distribution Management Relay utilizes both the Motorola 68332 32-bit microprocessor and the Grid Connect DSTni-LX Turbo 186 16-bit microprocessor to control and safeguard the assigned system. The former microprocessor measures logic inputs and analog signals, outputs all analog signals, and manages all output relays. Meanwhile, the latter microprocessor handles the liquid-crystal display, LEDs, and all communications. The two work in tandem to provide holistic monitoring and protection of the feeder distribution system. 

The relay’s automatic reclosing feature differentiates it from its 750 counterparts. In the event that a circuit or line experiences an overcurrent, the recloser can deenergize and protect the threatened components. The advantage of a recloser is that it can assess if the problem has resolved; if it has been, the line or circuit can be energized once again and the system can resume normal operation. The recloser feature makes the 760-P5-G5-D5-HI-A1-R especially well-suited for overhead feeders because automatic reclosing is typically necessary for these systems. 

The 760-P5-G5-D5-HI-A1-R is equipped with two phase TOC elements, each of which can be programmed by the user to specify voltage restraint, pickup current level for trip/alarm, and one of fifteen curve shapes. These curves include more standard ANSI, IEC, and IAC subtypes in addition to General Electric Multilin’s FlexCurve technology. The relay initiates a breaker trip or alarm when overcurrent magnitude and duration reach user-set parameters, shielding equipment from harm and prolonging system life.

Frequently Asked Questions about 760-P5-G5-D5-HI-A1-R

What does it mean when the "BRKR STATE BYPASS" is disabled for the GE Feeder Management Relay 760-P5-G5-D5-HI-A1-R?
For the GE Feeder Management Relay 760-P5-G5-D5-HI-A1-R when the "BRKR STATE BYPASS" setpoint is disabled, it means that the logic allows a trip circuit to be monitored when the only when the breaker is closed. A closed circuit has to be monitored when the breaker is opened.
Does the GE Feeder Management Relay's have circuit breakers that are 52a auxiliary contact for the 760-P5-G5-D5-HI-A1-R?
Yes, the circuit breakers are equipped with a standard control circuit that has a 52a auxiliary contact. It only allows the relay to trip when the breaker is closed. When is this breaker state, a trickle current is flowing through the trip circuitry and the 52a auxiliary contact is closed.
Is the 52b auxiliary contact also closed just like the 52a auxiliary for the 760-P5-G5-D5-HI-A1-R GE Feeder Management Relay?
The 52b auxiliary contact in similar to the 52a auxiliary contact, but the 52b auxiliary contact only lets the breaker to close when it is open. A closed breaker is when the 52b is open and there is no trickle of current that can flow. When the close coil supervision monitoring function is disabled, is when the breaker postion monitoring inputs are detecting a closed breaker.

Reviews For 760-P5-G5-D5-HI-A1-R

Internal Review
(5.0)

The 760-P1-G1-S1-LO-A20-R reclosure feature advantages it over the 750 and makes it an excellent choice for your energy system. The recloser can open a line when detecting overcurrent and reclose it in the event that system conditions are safe. -AX Control Tech Team

Repair Services For 760-P5-G5-D5-HI-A1-R

Type Lead Time Price Action
Repair Service 1-2 weeks $1258

Our highly skilled technicians can repair your 760-P5-G5-D5-HI-A1-R. All of our repairs come with a 3 Year AX Control Warranty. Please contact us for additional information about our repair process. To receive the repair pricing and lead time listed above please process your repair order via our website. The following repair options may be available upon request:

  • 48-72hr Rush Repair
  • Detailed Repair Reports
  • AX Control Certificate of Warranty

AX Control Warranty Info

All products we sell are backed by our unparalleled warranty. A warranty certificate will be provided with your order upon request.
All PLCs, HMIs, and Turbine Control Boards: 3 Years
All AC/DC and Servo Drives: 2 Years
All Motors: 1 Year
Learn More